Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2023.05.006 ↗Kurz gefasst
Metaanalyse in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Péter Tajti und 9 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Prosthodontics, Semmelweis University, Budapest, Hungary; PhD student, Centre for Translational Medicine, Semmelweis Universi…. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Metal Ceramic Alloys, Zirconium. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Technical complication rates of standard metal-ceramic implant-supported posterior restorations are relatively high. Whether monolithic zirconia crowns represent a more successful alternative is unclear. PURPOSE: The purpose of this systematic review and meta-analysis was to compare the clinical outcomes of posterior monolithic zirconia and metal-ceramic implant-supported single crowns. MATERIAL AND METHODS: A search was conducted in MEDLINE, Scopus, Embase, Web of Science, and CENTRAL databases for randomized controlled trials up to April 2023 with a follow-up time of at least 1 year. Restoration and implant survival and failure rates, marginal bone loss (MBL), bleeding on probing (BOP), and technical complications were analyzed by 2 reviewers. Statistical analyses were conducted using the R-statistics software program. The risk of bias was assessed by the Cochrane Risk of Bias Tool 2 (RoB 2), and the certainty of evidence by the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. RESULTS: A total of 11 out of 2030 records were identified by title and abstract, and 4 records were included after full-text analysis. The statistical analysis revealed no significant difference in MBL (MD -0.11, 95% CI: [-0.25; 0.03]), BOP (OR 0.66, 95% CI: [0.25; 1.77]), or implant failure (OR 1.30, 95% CI: [0.24; 7.08]). Monolithic zirconia presented significantly less chipping over 1 year (OR 0.17, 95% CI: [0.03; 0.99]). The chipping rate was 0% for monolithic zirconia and 7.61% for metal-ceramic. Based on a narrative review, the restoration survival rate was 97.5% in the monolithic zirconia group and 99.1% in the metal-ceramic group. CONCLUSIONS: Monolithic zirconia showed favorable short-term survival rates and had significantly less chipping over 1 year. Regarding MBL, BOP, and failure rates, both restoration types presented similar results at the 1-year follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Resident, Department of Prosthodontics, Semmelweis University, Budapest, Hungary; PhD student, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Clinical Specialist, Department of Periodontology, Semmelweis University, Budapest, Hungary; PhD student, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Resident, Department of Periodontology, Semmelweis University, Budapest, Hungary; Scientific Methodology Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Biostatistician, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Assistant Professor, Department of Conservative Dentistry, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Director, Associate Professor, Department of Community Dentistry, Semmelweis University, Budapest, Hungary; Supervisor, Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
Zitieren
APA
Tajti, P., Solyom, E., Czumbel, L. M., Szabó, B., Fazekas, R., Németh, O., Hermann, P., Gerber, G., Hegyi, P., & Mikulás, K. (2024). Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.05.006
Vancouver
Tajti P, Solyom E, Czumbel LM, Szabó B, Fazekas R, Németh O, et al. Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2023.05.006
BibTeX
@article{Tajti2024,
author = {Tajti, Péter and Solyom, Eleonora and Czumbel, László Márk and Szabó, Bence and Fazekas, Réka and Németh, Orsolya and Hermann, Péter and Gerber, Gábor and Hegyi, Péter and Mikulás, Krisztina},
title = {Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2023.05.006}
}
EUVIMED