Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns
The Journal of Prosthetic Dentistry · 2023
DOI: 10.1016/j.prosdent.2023.03.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023. Verfasst von Mazen A Attia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt. Electronic address: mazen.ahme…. Hauptthemen laut MEDLINE: Dental Marginal Adaptation, Crowns. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 61 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Polyetheretherketone (PEEK) has been increasingly used as a framework material in prosthetic dentistry. However, data on the marginal and internal fit of PEEK restorations fabricated by using either the computer-aided design and computer-aided manufacturing (CAD-CAM) or heat-pressing technique are sparse. PURPOSE: The aim of this in vitro study was to assess the marginal and internal fit of milled and pressed PEEK single crowns by using microcomputed tomography (μCT). MATERIAL AND METHODS: A custom-made, single stainless-steel die was designed to replicate a maxillary first premolar prepared for a ceramic crown. PEEK copings (N=30) were fabricated and allocated to 3 groups (n=10) according to the fabrication technique: milled from a prefabricated PEEK blank, heat pressed from PEEK pellets, and heat pressed from PEEK granules. All copings were veneered with a composite resin material. The marginal fit was recorded at 4 predetermined points and the internal fit at 8 predetermined points on each crown by using μCT. Two-way ANOVA, pair-wise Tukey honestly significant difference (HSD), and simple main effect tests were used for statistical analysis of the data (α=.05). RESULTS: Concerning marginal fit, the milled crowns demonstrated the best marginal fit overall (44 ±3 μm), followed by those pressed from pellets (92 ±3 μm), and finally by those pressed from granules (137 ±7 μm) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt. Electronic address: mazen.ahmed@dent.bsu.edu.eg.
- Professor, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom.
- PhD Researcher, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom.
- Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt.
Zitieren
APA
Attia, M. A., Blunt, L., Bills, P., Tawfik, A., & Radawn, M. (2023). Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.03.018
Vancouver
Attia MA, Blunt L, Bills P, Tawfik A, Radawn M. Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns. The Journal of Prosthetic Dentistry. 2023. doi:10.1016/j.prosdent.2023.03.018
BibTeX
@article{Attia2023,
author = {Attia, Mazen A and Blunt, Liam and Bills, Paul and Tawfik, Ahmed and Radawn, Mohamed},
title = {Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns},
journal = {The Journal of Prosthetic Dentistry},
year = {2023},
doi = {10.1016/j.prosdent.2023.03.018}
}
EUVIMED