Surface hardness and wear resistance of prefabricated and CAD‐CAM milled artificial teeth: A cross‐over clinical study
Journal of Prosthodontics · 2025
DOI: 10.1111/jopr.13890 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Sarah Abdelaal Ali und 3 weiteren Autor:innen. Beteiligte Einrichtung: External Residence of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt. Hauptthemen laut MEDLINE: Computer-Aided Design, Tooth, Artificial, Dental Restoration Wear, Denture, Complete. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 64 Literaturangaben.
Abstract (Originalsprache)
Purpose
To clinically evaluate the surface roughness and wear resistance of prefabricated and CAD‐CAM milled acrylic resin teeth for complete dentures. Materials and methods In a cross‐over study design, 10 completely edentulous patients were randomly included in this study and given two complete dentures. The first complete denture was made using prefabricated teeth, while the second was constructed using CAD‐CAM milled teeth. Following insertion (T0), 3 months (T3), and 6 months (T6), the complete dentures were scanned. Utilizing 3D surface super‐imposition techniques, the vertical (2D wear), and volumetric (3D wear) material loss were measured. The hardness of the teeth was evaluated at the time of denture insertion (T0) and then after 6 months (T6) of denture insertion by digital Vickers hardness tester. Statistical analysis was done using SPSS software. Paired groups were compared by paired t ‐test. Also, a repeated measure test was used. The significant difference was considered if p ≤ 0.05.
Results
The time of denture function was linearly correlated with the wear of the prefabricated and CAD‐CAM milled denture tooth. Prefabricated acrylic teeth had significantly more vertical and volumetric wear after 3 and 6 months, compared to CAD‐CAM milled denture teeth where p ‐values were 0.01, 0.009, 0.003, and 0.024, respectively. Additionally, CAD‐CAM milled teeth displayed significantly higher hardness values than prefabricated teeth both before and after 6 months of use where p ‐values were 0.001. After 6 months, all studied teeth showed a decrease in their hardness.
Conclusions
In terms of wear resistance and surface hardness, CAD‐CAM milled acrylic resin teeth were superior to prefabricated acrylic resin artificial teeth once the complete denture functions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- External Residence of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
- Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
- Prosthodontics Department, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, Riyadh, Saudi Arabia.
- Dental Biomaterials Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
ORCID-Profile: Sarah Abdelaal Ali, Heba Wageh Abozaed, Husn A Jazar, Aisha Z H Mostafa
Zitieren
APA
Ali, S. A., Abozaed, H. W., Jazar, H. A., & Mostafa, A. Z. H. (2025). Surface hardness and wear resistance of prefabricated and CAD‐CAM milled artificial teeth: A cross‐over clinical study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13890
Vancouver
Ali SA, Abozaed HW, Jazar HA, Mostafa AZH. Surface hardness and wear resistance of prefabricated and CAD‐CAM milled artificial teeth: A cross‐over clinical study. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13890
BibTeX
@article{Ali2025,
author = {Ali, Sarah Abdelaal and Abozaed, Heba Wageh and Jazar, Husn A and Mostafa, Aisha Z H},
title = {Surface hardness and wear resistance of prefabricated and CAD‐CAM milled artificial teeth: A cross‐over clinical study},
journal = {Journal of Prosthodontics},
year = {2025},
doi = {10.1111/jopr.13890}
}
EUVIMED