Accuracy of 2 direct digital scanning techniques—intraoral scanning and stereophotogrammetry—for complete arch implant-supported fixed prostheses: A prospective study
The Journal of Prosthetic Dentistry · 2023-10 · 130 (4) · 564-572
DOI: 10.1016/j.prosdent.2022.03.033 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023-10. Verfasst von Yuwei Yan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, P…. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 67 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Conventional impression techniques for complete arch implant-supported prostheses are technique-sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer an alternative to conventional impression making. PURPOSE: The purpose of this prospective study was to compare the accuracy of IOS and SPG for complete arch implant scans and to evaluate the passive fit of frameworks fabricated with SPG. MATERIAL AND METHODS: Laboratory scanning of gypsum casts, SPG, and IOS were performed for all participants. The data regarding the abutment platform were superimposed to calculate the 3D deviation of SPG and IOS compared with that of laboratory scanning as an evaluation of accuracy. The effect of implant position and number on accuracy was analyzed. The more accurate technique between SPG and IOS was used to fabricate the titanium frameworks, as was laboratory scanning. The passive fit of the frameworks was assessed by clinical examination, the Sheffield test, and panoramic radiography. RESULTS: Seventeen participants (21 arches, 120 implants) were included. The accuracy of SPG ranged from 2.70 μm to 92.80 μm, with a median (Q1, Q3) of 17.00 (11.68, 22.50) μm, which was significantly more accurate than that of IOS, ranging from 21.30 μm to 815.60 μm, with a median (Q1, Q3) of 48.95 (34.78, 75.88) μm. No significant correlation was found between position or number of implants and 3D deviation in the SPG group. A weak positive correlation was found between implant number and 3D deviation in the IOS group. SPG and laboratory scanning were used to fabricate titanium frameworks. The passive fit between the frameworks and abutment platforms was confirmed. CONCLUSIONS: SPG, which was not affected by position or number of implants, was more accurate than IOS and comparable with laboratory scanning. The frameworks fabricated based on SPG and laboratory scanning were comparable in their passive fit. The SPG technique may be an alternative to laboratory scanning for complete arch implant scans.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China.
- Attending physician, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China.
- Professor, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China. Electronic address: gengwei717@aliyun.com.
Zitieren
APA
Yan, Y., Lin, X., Yue, X., & Geng, W. (2023). Accuracy of 2 direct digital scanning techniques—intraoral scanning and stereophotogrammetry—for complete arch implant-supported fixed prostheses: A prospective study. The Journal of Prosthetic Dentistry, 130(4), 564-572. https://doi.org/10.1016/j.prosdent.2022.03.033
Vancouver
Yan Y, Lin X, Yue X, Geng W. Accuracy of 2 direct digital scanning techniques—intraoral scanning and stereophotogrammetry—for complete arch implant-supported fixed prostheses: A prospective study. The Journal of Prosthetic Dentistry. 2023;130(4):564-572. doi:10.1016/j.prosdent.2022.03.033
BibTeX
@article{Yan2023,
author = {Yan, Yuwei and Lin, Xiao and Yue, Xinxin and Geng, Wei},
title = {Accuracy of 2 direct digital scanning techniques—intraoral scanning and stereophotogrammetry—for complete arch implant-supported fixed prostheses: A prospective study},
journal = {The Journal of Prosthetic Dentistry},
year = {2023},
volume = {130},
number = {4},
pages = {564--572},
doi = {10.1016/j.prosdent.2022.03.033}
}
EUVIMED