EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the reproducibility and factors affecting perfusion measurement in normal pregnancies with single-slice FAIR Arterial Spin Labeling (ASL)

A Jungelson, R Bartin, C Arthuis, C Henry, M Taso, D C Alsop, L Bussières, Y Ville, L J Salomon, D Grévent

Placenta · 2026-05 · 179 · 121-127

DOI: 10.1016/j.placenta.2026.04.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Placenta, 2026-05. Verfasst von A Jungelson und 9 weiteren Autor:innen. Beteiligte Einrichtung: URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France. Hauptthemen laut MEDLINE: Placenta, Placental Circulation. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the reproducibility of the FAIR ASL in placental perfusion and to identify potential factors influencing the signal and measurements obtained in normal pregnancies. METHODS: 66 uncomplicated pregnancies were prospectively included. MRI scans were performed on a 1.5 T scanner. Perfusion maps were acquired with a 10-mm axial single SSFSE slice, repeated 3 times with variable selective pulse thickness (30 mm, 50 mm and 70 mm). To assess reproducibility, the sequences were performed twice either consecutively or by removing the patient from the MRI between the two acquisitions. We also studied the impact of potential factors on perfusion including placental location, women's position in the scanner, maternal age and gestational age (GA) at MRI. RESULTS: The mean placental blood flow was 323.5 ± 93.7 mL/100 g/min, 213.8 ± 62.4 mL/100 g/min, and 175.6 ± 57.4 mL/100 g/min for inversion pulse thicknesses of 30 mm, 50 mm, and 70 mm, respectively (p < 0.01). Reproducibility of FAIR ASL was highest when using the 70-mm inversion pulse thickness, with perfusion estimates consistent with previously reported values. No significant association was found with maternal age or maternal position. CONCLUSIONS: Our results suggest that the use of a 70-mm pulse thickness is most likely to provide a reproducible and reliable assessment of placental perfusion. Further studies are necessary to improve stability before translating into clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlacentaPlacental CirculationHumansFemalePregnancyReproducibility of ResultsAdultSpin LabelsMagnetic Resonance ImagingPerfusion Magnetic Resonance ImagingProspective StudiesYoung AdultGestational Age

Stichwörter der Autor:innen

FAIR ASLMRIPerfusionPlacentaReproducibility

Substanzen

Spin Labels

Autor:innen und Institutionen

  • URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France.
  • URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France; Service de Gynécologie-Obstétrique, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France. Electronic addre…
  • URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France; Service de Gynécologie-Obstétrique, Hôpital Mère-Enfant, CHU Nantes, Nantes, France.
  • Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA.
  • URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France; Service de Gynécologie-Obstétrique, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.
  • URP FETUS 7328 and LUMIERE Platform, Université de Paris, Paris, France; Service de Radiologie, Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Zitieren

APA

Jungelson, A., Bartin, R., Arthuis, C., Henry, C., Taso, M., Alsop, D. C., Bussières, L., Ville, Y., Salomon, L. J., & Grévent, D. (2026). Evaluation of the reproducibility and factors affecting perfusion measurement in normal pregnancies with single-slice FAIR Arterial Spin Labeling (ASL). Placenta, 179, 121-127. https://doi.org/10.1016/j.placenta.2026.04.006

Vancouver

Jungelson A, Bartin R, Arthuis C, Henry C, Taso M, Alsop DC, et al. Evaluation of the reproducibility and factors affecting perfusion measurement in normal pregnancies with single-slice FAIR Arterial Spin Labeling (ASL). Placenta. 2026;179:121-127. doi:10.1016/j.placenta.2026.04.006

BibTeX
@article{Jungelson2026,
  author = {Jungelson, A and Bartin, R and Arthuis, C and Henry, C and Taso, M and Alsop, D C and Bussières, L and Ville, Y and Salomon, L J and Grévent, D},
  title = {Evaluation of the reproducibility and factors affecting perfusion measurement in normal pregnancies with single-slice FAIR Arterial Spin Labeling (ASL)},
  journal = {Placenta},
  year = {2026},
  volume = {179},
  pages = {121--127},
  doi = {10.1016/j.placenta.2026.04.006}
}
Kostenlos starten →