Reproducibility of Metabolic Mapping Using 2D Multi‐Slice Short‐TE and GABA‐Edited Spin‐Echo MRSI at 3T in a Single Protocol
NMR in Biomedicine · 2026
DOI: 10.1002/nbm.70175 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Helge J Zöllner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: gamma-Aminobutyric Acid, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIA NIH HHS, NINDS NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
MRSI is a non‐invasive tool for mapping metabolic distributions in multi‐focal or other diseases where the location of abnormalities may be uncertain. High‐concentration metabolites can be investigated at 3T using non‐edited MRSI, whereas lower‐concentration metabolites, such as GABA, typically require specialized editing techniques because of spectral overlap. This study reports on the reproducibility of a protocol containing both co‐localized short‐TE and GABA‐edited multi‐slice spin‐echo 2D MRSI. Multi‐slice, short‐TE (TE 20 ms) and GABA‐edited (TE 68 ms) MRSI at a nominal spatial resolution of 2.2 cm 3 was performed twice (7 to 14 days apart) at 3T on 11 healthy volunteers (age range 7 to 43 years). Data analysis was performed in the “Osprey” software package, including retrospective motion compensation, consensus‐recommended processing, and linear‐combination modeling. Metabolite estimates for six metabolites were quantified relative to total creatine (tCr) and water in 14 regions of interest. Reproducibility was assessed using intra‐ and inter‐subject coefficients of variation. Short‐TE MRSI metabolite estimates for total N‐acetylaspartate (tNAA), tCr, total choline (tCho), myo‐inositol (mI), and the sum of glutamate and glutamine (Glx) were found to be highly reproducible for both creatine‐ and water‐referenced concentration estimates, with 77% of the regions of interest meeting the quality‐control criteria for both visits and 96% for at least one visit. Average intra‐subject CVs were 5.8% and 4.8%, and inter‐subject CVs were 11.1% and 9.7% for water‐referenced and tCr‐referenced estimates, respectively. For GABA+ (GABA + macromolecules) estimates, 46% of the voxels of interest met quality‐control criteria for both visits, and 82% for at least one visit. In the remaining datasets, the average intra‐subject CVs were 13.5% for both quantification methods, and the inter‐subject CVs were 13.5% and 16.9% for water‐referenced and creatine‐referenced estimates, respectively. 3T‐MRSI sequences can achieve reproducible mapping with extended brain coverage of five major metabolites (tNAA, tCr, tCho, mI, and Glx). Reproducibility assessment for GABA+ mapping remains challenging, with 18% of the data being rejected in at least one visit, but it yielded acceptable reproducibility in datasets that met quality control criteria in both visits (46%).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Biomedical Engineering, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
ORCID-Profile: Helge J Zöllner, Kimberly L Chan, Peter B Barker
Förderung
- NIA NIH HHS
- NINDS NIH HHS
- NIBIB NIH HHS
- NIH HHS
- US Department of Defense
- U.S. Department of Defense
- National Institutes of Health
Zitieren
APA
Zöllner, H. J., Senapati, D. K., Özdemir, İ., Chan, K. L., Oeltzschner, G., Lin, D. D. M., & Barker, P. B. (2026). Reproducibility of Metabolic Mapping Using 2D Multi‐Slice Short‐TE and GABA‐Edited Spin‐Echo MRSI at 3T in a Single Protocol. NMR in Biomedicine. https://doi.org/10.1002/nbm.70175
Vancouver
Zöllner HJ, Senapati DK, Özdemir İ, Chan KL, Oeltzschner G, Lin DDM, et al. Reproducibility of Metabolic Mapping Using 2D Multi‐Slice Short‐TE and GABA‐Edited Spin‐Echo MRSI at 3T in a Single Protocol. NMR in Biomedicine. 2026. doi:10.1002/nbm.70175
BibTeX
@article{Zllner2026,
author = {Zöllner, Helge J and Senapati, Dillip K and Özdemir, İpek and Chan, Kimberly L and Oeltzschner, Georg and Lin, Doris D M and Barker, Peter B},
title = {Reproducibility of Metabolic Mapping Using 2D Multi‐Slice Short‐TE and GABA‐Edited Spin‐Echo MRSI at 3T in a Single Protocol},
journal = {NMR in Biomedicine},
year = {2026},
doi = {10.1002/nbm.70175}
}
EUVIMED