Quantitative static contrast-enhanced phantom study to establish performance of advanced cone beam computed tomography for functional imaging applications
Physics and Imaging in Radiation Oncology · 2026-11 · 42 · 101125
DOI: 10.1016/j.phro.2026.101125 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2026-11. Verfasst von Riley McMaster und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Varian Medical Systems Inc, University of Toronto Department of Medical Biophysics.
Abstract (Originalsprache)
Background and purpose: Dynamic contrast-enhanced computed tomography (DCE-CT) is a quantitative imaging technique that measures vascular perfusion. Extending this to cone beam CT (CBCT) would enable functional measurements on radiotherapy machines. An advanced CBCT imaging solution, with enhanced image quality and rapid acquisitions, offers potential. However, the static quantitative and spatial performance of advanced CBCT relevant to DCE imaging has not been characterized. Materials and methods: To address this, the image quality of advanced CBCT was compared with standard CBCT and CT using contrast-enhanced phantoms with DCE-specific characteristics not previously applied to CBCT. A contrast enhancement CT (CECT) phantom (acrylic cylinder with capsule inserts) and a humanoid phantom (human torso with a liver containing tumour-mimicking spheres) were imaged across different acquisition settings. Results: Using the CECT phantom, advanced CBCT demonstrated improved CT number accuracy compared to standard CBCT (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
- Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada.
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada.
Förderung
- Varian Medical Systems Inc
- University of Toronto Department of Medical Biophysics
Zitieren
APA
McMaster, R., Marants, R., Mohseni, H., & Coolens, C. (2026). Quantitative static contrast-enhanced phantom study to establish performance of advanced cone beam computed tomography for functional imaging applications. Physics and Imaging in Radiation Oncology, 42, 101125. https://doi.org/10.1016/j.phro.2026.101125
Vancouver
McMaster R, Marants R, Mohseni H, Coolens C. Quantitative static contrast-enhanced phantom study to establish performance of advanced cone beam computed tomography for functional imaging applications. Physics and Imaging in Radiation Oncology. 2026;42:101125. doi:10.1016/j.phro.2026.101125
BibTeX
@article{McMaster2026,
author = {McMaster, Riley and Marants, Raanan and Mohseni, Hedi and Coolens, Catherine},
title = {Quantitative static contrast-enhanced phantom study to establish performance of advanced cone beam computed tomography for functional imaging applications},
journal = {Physics and Imaging in Radiation Oncology},
year = {2026},
volume = {42},
pages = {101125},
doi = {10.1016/j.phro.2026.101125}
}
EUVIMED