Enhanced Visualization: Transforming Non-Contrast into Contrast-Enhanced Computed Tomography Images Through Advanced Generative Adversarial Networks
Diagnostics · 13.03.2026 · 16 (6) · 861
DOI: 10.3390/diagnostics16060861 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 13.03.2026. Verfasst von Hyun Soo Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Bucheon 14627, Republic of Korea. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Polestar Healthcare Inc., Seoul, South Korea.
Abstract (Originalsprache)
Background/Objectives: Contrast-enhanced CT (CECT) is essential for mediastinal and lymph node assessment but is often limited in patients with renal dysfunction, prior severe contrast reactions, or pediatric populations. Deep learning approaches, such as generative adversarial networks (GANs), allow the generation of synthetic CECT (sCECT) from non-contrast CT (NCCT) without contrast injection. Materials and Methods: A GAN-based model was trained using 400 CECT scans acquired between March and July 2024. The model was tested in 20 patients with lymphoma or metastatic lymphadenopathy diagnosed between January and July 2025, using only NCCT scans. Quantitative evaluation compared sCECT with CECT using Mean Absolute Error (MAE), Root Mean Square Error (RMSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), and Pearson Correlation Coefficient (PCC). Two radiologists performed qualitative assessment, and Signal-to-Noise Ratio (SNR)/Contrast-to-Noise Ratio (CNR) values were measured for thoracic structures.
Results
Compared with NCCT, sCECT demonstrated slightly lower MAE (20.87 ± 8.84 vs. 21.26 ± 9.26) and RMSE (45.22 ± 14.22 vs. 45.94 ± 15.07), and marginally higher PSNR (15.44 ± 2.70 vs. 15.38 ± 3.02), indicating modest improvements in pixel-wise similarity. SSIM values were comparable (0.610 ± 0.09 vs. 0.63 ± 0.10), while PCC decreased (0.61 ± 0.09 vs. 0.77 ± 0.15). All differences were statistically significant (p < 0.001). Despite these mixed quantitative results, sCECT was qualitatively rated significantly higher by radiologists, with improved visualization of mediastinal structures. SNR and CNR analyses further supported enhanced contrast depiction in sCECT compared with NCCT.
Conclusions
The GAN-based model successfully generated sCECT from NCCT with modest quantitative similarity gains but clear qualitative improvement, particularly for mediastinal lymph node evaluation. Although synthetic enhancement represents a learned intensity transformation rather than true iodine-based attenuation, sCECT may serve as a valuable adjunct in patients with contraindications to iodinated contrast.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Bucheon 14627, Republic of Korea.
- The AI R&D Center, Polestar Healthcare Inc., Seoul 06621, Republic of Korea.
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
ORCID-Profile: Hyun Soo Kim, Bo Mi Gil
Förderung
- Polestar Healthcare Inc., Seoul, South Korea
Zitieren
APA
Kim, H. S., Gil, B. M., Kim, T., Yoon, Y. D., & Han, D. H. (2026). Enhanced Visualization: Transforming Non-Contrast into Contrast-Enhanced Computed Tomography Images Through Advanced Generative Adversarial Networks. Diagnostics, 16(6), 861. https://doi.org/10.3390/diagnostics16060861
Vancouver
Kim HS, Gil BM, Kim T, Yoon YD, Han DH. Enhanced Visualization: Transforming Non-Contrast into Contrast-Enhanced Computed Tomography Images Through Advanced Generative Adversarial Networks. Diagnostics. 2026;16(6):861. doi:10.3390/diagnostics16060861
BibTeX
@article{Kim2026,
author = {Kim, Hyun Soo and Gil, Bo Mi and Kim, Taehwan and Yoon, Yeo Dong and Han, Dae Hee},
title = {Enhanced Visualization: Transforming Non-Contrast into Contrast-Enhanced Computed Tomography Images Through Advanced Generative Adversarial Networks},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {6},
pages = {861},
doi = {10.3390/diagnostics16060861}
}