EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium

Jaafar EL Bakkali, Abderrahim Doudouh, Hamid Mansouri

Physics in Medicine · 2018

DOI: 10.1016/j.phmed.2017.08.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine, 2018. Verfasst von Jaafar EL Bakkali und 2 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study is the assessment of the Geant4 capabilities in accurately modeling of dose distribution in a heterogeneous water phantom. In this purpose, a Geant4 user code has been designed and developed to enable an accurate modeling of cross beam profiles in a heterogeneous water phantom deposited by a 12 MV photon beam emitted by a Saturne 43 Linac head and configuring a 10 × 10 cm2 radiation field. The calculated cross beam profiles at two distinct depths (22 cm and 25 cm), were compared to the ones obtained with MCNPX code. Our findings show that the shapes of dosimetric curves at two distinct depths calculated with Geant4 code and the ones obtained by MCNPX code are in a very good agreement. However, the Geant4 code seems painfully slow when calculating those dosimetric curves and its associated statistical uncertainties don't seem to reach 1% after two weeks of calculations. To deal with this issue, we suggest that a new variance reduction technique specially addressed for dose calculation in a heterogeneous medium must be developed by the Geant4 collaboration, in order to decrease the required computing time and to improve the statistical of calculations.

Zitieren

APA

Bakkali, J. E., Doudouh, A., & Mansouri, H. (2018). Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium. Physics in Medicine. https://doi.org/10.1016/j.phmed.2017.08.001

Vancouver

Bakkali JE, Doudouh A, Mansouri H. Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium. Physics in Medicine. 2018. doi:10.1016/j.phmed.2017.08.001

BibTeX
@article{Bakkali2018,
  author = {Bakkali, Jaafar EL and Doudouh, Abderrahim and Mansouri, Hamid},
  title = {Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous medium},
  journal = {Physics in Medicine},
  year = {2018},
  doi = {10.1016/j.phmed.2017.08.001}
}