EUVIMEDEUVIMED entdecken
Crossref

Real-time fluorescence imaging with indocyanine green during laparoscopic duodenum-preserving pancreatic head resection

Jian Huang, Wei Hu, Jinghang Liu, Xinguo Tang, Yuting Fan, Longjian Ran, Bowen Li, Jia Zhang, Hu Xiong, Wen Li, Bo Liang, Lu Fang und 1 weitere

Pancreatology · 2024

DOI: 10.1016/j.pan.2023.11.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pancreatology, 2024. Verfasst von Jian Huang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China. Hauptthemen laut MEDLINE: Laparoscopy, Bile Duct Diseases. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Laparoscopic duodenum-preserving pancreatic head resection (LDPPHR) is a surgical method used to treat benign and low-grade malignant pancreatic head tumors. This study aimed to determine the protective effect of common bile duct in LDPPHR using indocyanine green (ICG) fluorescence imaging. METHODS: A retrospective analysis of 30 patients treated with LDPPHR at the Second Affiliated Hospital of Nanchang University between January 2015 and November 2022 was performed. Patients were divided into two groups based on ICG use: ICG and non-ICG. RESULTS: Thirty patients received LDPPHR, 11 males and 19 females, and the age was 50.50 (M (IQR)) years (range: 19-76 years). LDPPHR was successfully performed in 27 (90 %) patients, LPD was performed in 1 (3 %) patient, and laparotomy conversion was performed in 2 (7 %) patients. One patient (3 %) died 21 days after surgery. The incidence of intraoperative bile duct injury in the ICG group was lower than that in the non-ICG group (10 % vs 60 %, P = 0.009), and the operation time in the ICG group was shorter than that in the non-ICG group (311.9 ± 14.97 vs 338.05 ± 18.75 min, P < 0.05). Postoperative pancreatic fistula occurred in 16 patients (53 %), including 10 with biochemical leakage (62.5 %), four with grade B (25 %), and two with grade C (12.5 %). Postoperative bile leakage occurred in four patients (13 %). CONCLUSIONS: The ICG fluorescence imaging technology in LDPPHR helps protect the integrity of the common bile duct and reduce the occurrence of intraoperative bile duct injury, postoperative bile leakage, and bile duct stenosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopyBile Duct DiseasesMaleFemaleHumansIndocyanine GreenRetrospective StudiesOptical ImagingDuodenum

Stichwörter der Autor:innen

Common bile ductFluorescence imagingLaparoscopicPancreatectomy

Substanzen

Indocyanine Green

Autor:innen und Institutionen

  • Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China.
  • Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China. Electronic address: fanglu@medmail.com.cn.
  • Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China. Electronic address: 754027611@qq.com.

Zitieren

APA

Huang, J., Hu, W., Liu, J., Tang, X., Fan, Y., Ran, L., Li, B., Zhang, J., Xiong, H., Li, W., Liang, B., Fang, L., & Fu, X. (2024). Real-time fluorescence imaging with indocyanine green during laparoscopic duodenum-preserving pancreatic head resection. Pancreatology. https://doi.org/10.1016/j.pan.2023.11.010

Vancouver

Huang J, Hu W, Liu J, Tang X, Fan Y, Ran L, et al. Real-time fluorescence imaging with indocyanine green during laparoscopic duodenum-preserving pancreatic head resection. Pancreatology. 2024. doi:10.1016/j.pan.2023.11.010

BibTeX
@article{Huang2024,
  author = {Huang, Jian and Hu, Wei and Liu, Jinghang and Tang, Xinguo and Fan, Yuting and Ran, Longjian and Li, Bowen and Zhang, Jia and Xiong, Hu and Li, Wen and Liang, Bo and Fang, Lu and Fu, Xiaowei},
  title = {Real-time fluorescence imaging with indocyanine green during laparoscopic duodenum-preserving pancreatic head resection},
  journal = {Pancreatology},
  year = {2024},
  doi = {10.1016/j.pan.2023.11.010}
}
Kostenlos starten →