Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection
World Journal of Surgery · 2025
DOI: 10.1002/wjs.12665 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Surgery, 2025. Verfasst von Ji Hoon Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea. Hauptthemen laut MEDLINE: Hepatectomy, Indocyanine Green, Liver Neoplasms, Laparoscopy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Background
Determining tumor location during laparoscopic hepatectomy is challenging due to the lack of direct liver palpation and limitations of intraoperative ultrasound. Advances in indocyanine green (ICG) fluorescence imaging have significantly enhanced real‐time visualization during hepatectomy, aiding in tumor detection and guiding resection margins. The present study assessed the clinical relevance of the detection by real‐time ICG imaging of a fluorescent rim on the cut surface of the liver in determining resection margins in patients undergoing laparoscopic hepatectomy for malignant liver tumors.
Methods
The present study evaluated patients who underwent laparoscopic hepatectomy using ICG fluorescence imaging from April 2020 to April 2023. If a fluorescent rim was detected on the cut surface of the liver during parenchymal transection, adjustments were made to the resection plane to ensure proper tumor clearance. The surgical transection plane was guided by real‐time ICG fluorescence imaging, ensuring precise resection margins.
Results
Of the 300 patients who underwent laparoscopic hepatectomy using ICG fluorescence imaging, 20 were positive for an ICG fluorescent rim on the cut surface of the liver during parenchymal transection. The median tumor size was 26 mm (range: 4–52 mm), and the median resection margin was 4.5 mm (range: 0.8–10 mm). The median postoperative hospital stay was 6 days (range: 5–21 days).
Conclusion
This study confirmed the preliminary safety of ICG fluorescence imaging in guiding resection margins during laparoscopic liver resection and provides technical insights into parenchymal preservation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea.
- Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
ORCID-Profile: Ji Hoon Kim
Zitieren
APA
Kim, J. H., & Park, H. M. (2025). Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection. World Journal of Surgery. https://doi.org/10.1002/wjs.12665
Vancouver
Kim JH, Park HM. Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection. World Journal of Surgery. 2025. doi:10.1002/wjs.12665
BibTeX
@article{Kim2025,
author = {Kim, Ji Hoon and Park, Hyeong Min},
title = {Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection},
journal = {World Journal of Surgery},
year = {2025},
doi = {10.1002/wjs.12665}
}