EUVIMEDEUVIMED entdecken
Crossref

Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection

Ji Hoon Kim iD, Hyeong Min Park

World Journal of Surgery · 2025

DOI: 10.1002/wjs.12665 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Surgery, 2025. Verfasst von Ji Hoon Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea. Hauptthemen laut MEDLINE: Hepatectomy, Indocyanine Green, Liver Neoplasms, Laparoscopy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Determining tumor location during laparoscopic hepatectomy is challenging due to the lack of direct liver palpation and limitations of intraoperative ultrasound. Advances in indocyanine green (ICG) fluorescence imaging have significantly enhanced real‐time visualization during hepatectomy, aiding in tumor detection and guiding resection margins. The present study assessed the clinical relevance of the detection by real‐time ICG imaging of a fluorescent rim on the cut surface of the liver in determining resection margins in patients undergoing laparoscopic hepatectomy for malignant liver tumors.

Methods

The present study evaluated patients who underwent laparoscopic hepatectomy using ICG fluorescence imaging from April 2020 to April 2023. If a fluorescent rim was detected on the cut surface of the liver during parenchymal transection, adjustments were made to the resection plane to ensure proper tumor clearance. The surgical transection plane was guided by real‐time ICG fluorescence imaging, ensuring precise resection margins.

Results

Of the 300 patients who underwent laparoscopic hepatectomy using ICG fluorescence imaging, 20 were positive for an ICG fluorescent rim on the cut surface of the liver during parenchymal transection. The median tumor size was 26 mm (range: 4–52 mm), and the median resection margin was 4.5 mm (range: 0.8–10 mm). The median postoperative hospital stay was 6 days (range: 5–21 days).

Conclusion

This study confirmed the preliminary safety of ICG fluorescence imaging in guiding resection margins during laparoscopic liver resection and provides technical insights into parenchymal preservation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HepatectomyIndocyanine GreenLiver NeoplasmsLaparoscopyOptical ImagingSurgery, Computer-AssistedHumansFemaleMaleMiddle AgedAgedMargins of ExcisionAdultAged, 80 and overRetrospective StudiesLiverClinical Relevance

Stichwörter der Autor:innen

ICG fluorescent imaginglaparoscopic liver resectionparenchymal sparing liver resection

Substanzen

Indocyanine Green

Autor:innen und Institutionen

  • Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea.
  • Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.

ORCID-Profile: Ji Hoon Kim

Zitieren

APA

Kim, J. H., & Park, H. M. (2025). Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection. World Journal of Surgery. https://doi.org/10.1002/wjs.12665

Vancouver

Kim JH, Park HM. Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection. World Journal of Surgery. 2025. doi:10.1002/wjs.12665

BibTeX
@article{Kim2025,
  author = {Kim, Ji Hoon and Park, Hyeong Min},
  title = {Clinical Significance of Real‐Time Guidance Using the ICG Fluorescent Rim on the Resection Plane During Liver Parenchymal Transection},
  journal = {World Journal of Surgery},
  year = {2025},
  doi = {10.1002/wjs.12665}
}
Kostenlos starten →