EUVIMEDEUVIMED entdecken
Systematische Übersicht

Minimum joint space width demonstrates higher inter‐ and intra‐observer reliability than Kellgren–Lawrence grading in knee osteoarthritis

Monty S Khela, Tiana Lee, Kellen L Mulford, Linjun Yang, Milos Brkljac, Derek Crossman, Michael J Taunton iD, Cody C Wyles iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-11 · 34 (11) · 4113-4124

DOI: 10.1002/ksa.70395 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 14.04.2026. Verfasst von Monty S Khela und 7 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Osteoarthritis, Knee, Knee Joint. Die Arbeit nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this systematic review was to compare the inter‐ and intra‐observer reliability of Kellgren–Lawrence (KL) grading versus minimum joint space width (mJSW) measurement on knee radiographs, and to examine the influence of rater type, radiographic view and atlas‐based training.

Methods

A systematic search of PubMed/MEDLINE, Embase, Scopus and Web of Science was conducted through July 2025 following Preferred Reporting Items for Systematic reviews and Meta‐Analyses (PRISMA) guidelines. Studies reporting inter‐ and/or intra‐observer reliability for KL or mJSW on standard knee radiographs were included. Extracted data included kappa ( κ ) and intraclass correlation coefficient (ICC) values, rater expertise, radiographic view and atlas usage. Raters were categorized as expert, trainee/non‐expert or artificial intelligence (AI)‐assisted/automated.

Results

Twenty‐four studies (10,394 radiographs) met the inclusion criteria. Inter‐observer reliability was generally higher for mJSW (mean ICC = 0.82 ± 0.17) compared with KL (mean k = 0.72 ± 0.17), with similar trends observed for intra‐observer reliability. Experts and AI‐assisted systems outperformed trainees/non‐experts for both metrics. Reliability improved with semiflexed posteroanterior/Rosenberg views and atlas‐guided training.

Conclusion

This systematic review demonstrates that mJSW measurement generally shows higher reproducibility than KL grading. Reliability improved with expertise, standardized imaging and structured training, and AI‐assisted approaches performed comparably to expert raters. Quantitative mJSW should complement KL grading, particularly when combined with alignment measures, to enhance consistency and clinical relevance of radiographic assessment. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Osteoarthritis, KneeKnee JointHumansReproducibility of ResultsObserver VariationRadiographySeverity of Illness Index

Stichwörter der Autor:innen

Kellgren–Lawrence gradinginter‐ and intra‐observer agreementknee osteoarthritisminimum joint space widthradiographic reliability

Autor:innen und Institutionen

  • Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.

ORCID-Profile: Michael J Taunton, Cody C Wyles

Zitieren

APA

Khela, M. S., Lee, T., Mulford, K. L., Yang, L., Brkljac, M., Crossman, D., Taunton, M. J., & Wyles, C. C. (2026). Minimum joint space width demonstrates higher inter‐ and intra‐observer reliability than Kellgren–Lawrence grading in knee osteoarthritis. Knee Surgery, Sports Traumatology, Arthroscopy, 34(11), 4113-4124. https://doi.org/10.1002/ksa.70395

Vancouver

Khela MS, Lee T, Mulford KL, Yang L, Brkljac M, Crossman D, et al. Minimum joint space width demonstrates higher inter‐ and intra‐observer reliability than Kellgren–Lawrence grading in knee osteoarthritis. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(11):4113-4124. doi:10.1002/ksa.70395

BibTeX
@article{Khela2026,
  author = {Khela, Monty S and Lee, Tiana and Mulford, Kellen L and Yang, Linjun and Brkljac, Milos and Crossman, Derek and Taunton, Michael J and Wyles, Cody C},
  title = {Minimum joint space width demonstrates higher inter‐ and intra‐observer reliability than Kellgren–Lawrence grading in knee osteoarthritis},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {11},
  pages = {4113--4124},
  doi = {10.1002/ksa.70395}
}
Kostenlos starten →