Fachartikel in der Zeitschrift Journal of Optometry, 2025. Verfasst von Rosa M Salmerón-Campillo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain; Visionapp Solutions S.L., Murcia, Spa…. Hauptthemen laut MEDLINE: Smartphone, Presbyopia, Mobile Applications, Eyeglasses. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: To evaluate the viability and accuracy of a mobile application (app) for subjective measurement of presbyopic addition, comparing its performance with standard clinical methods. METHODS: Twenty presbyopic subjects (aged 52 to 64) participated in the study. Clinical measurements of sphero-cylindrical refraction and its correction was achieved using trial lenses. Addition was also clinically measured using a standard and a tentative method. A set of 12 trial lenses ranging from 0 to 2.75 D were randomly put on top of the far distance correction, generating the correction addition correction or different levels of under/over correction of the addition. Participants then used a smartphone-based app to subjectively determine binocularly their near point (NP) using a push-up method while looking at a blue stimulus that rescaled as a function of the face-device distance measured using the front camera of the device. For each induced level of under/over correction of the addition, participants completed three measurements of their near point. RESULTS: Linear regression analysis showed a strong correlation (R² = 0.82) between app-measured and clinical addition values. Bland-Altman analysis revealed a mean over estimation of -0.22± 0.38 D with a limit of agreement of ±0.74 D of the near correction. Cumulative error analysis indicated that 61.7 % of app measurements were within 0.25 D of clinical values, and 82.5 % within 0.50 D CONCLUSIONS: A smartphone-based subjective measurement of presbyopic addition can potentially be used to assess the addition needed to detect the under or over corrected addition in full presbyopic subjects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain; Visionapp Solutions S.L., Murcia, Spain. Electronic address: rmsalmeroncampillo@gmail.com.
- Visionapp Solutions S.L., Murcia, Spain.
- Visionapp Solutions S.L., Murcia, Spain; CORL, Indiana University School of Optometry, Bloomington, IN, USA.
- Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain.
Zitieren
APA
Salmerón-Campillo, R. M., Diaz-Guirado, J. A., Martinez-Ros, G., Jaskulski, M., & López-Gil, N. (2025). Preliminary evaluation of smartphone-based addition measurement in a presbyopic population. Journal of Optometry. https://doi.org/10.1016/j.optom.2025.100561
Vancouver
Salmerón-Campillo RM, Diaz-Guirado JA, Martinez-Ros G, Jaskulski M, López-Gil N. Preliminary evaluation of smartphone-based addition measurement in a presbyopic population. Journal of Optometry. 2025. doi:10.1016/j.optom.2025.100561
BibTeX
@article{SalmernCampillo2025,
author = {Salmerón-Campillo, Rosa M and Diaz-Guirado, Jose A and Martinez-Ros, Gines and Jaskulski, Mateusz and López-Gil, Norberto},
title = {Preliminary evaluation of smartphone-based addition measurement in a presbyopic population},
journal = {Journal of Optometry},
year = {2025},
doi = {10.1016/j.optom.2025.100561}
}
EUVIMED