The influence of the tear film on the intraocular pressure and the corneal biomechanical properties analyzed with the Ocular Response Analyzer
Journal of Optometry · 2024-04 · 17 (2) · 100488
DOI: 10.1016/j.optom.2023.100488 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Optometry, 2024-04. Verfasst von Filipe Da Silva und 2 weiteren Autor:innen. Beteiligte Einrichtung: Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal. Electronic address: filipe.silva…. Hauptthemen laut MEDLINE: Intraocular Pressure, Glaucoma. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia.
Abstract (Originalsprache)
PURPOSE: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. METHODS: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. RESULTS: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal. Electronic address: filipe.silva.opt@gmail.com.
- Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal.
Förderung
- Fundação para a Ciência e a Tecnologia
Zitieren
APA
Da Silva, F., Linhares, J. M. M., & Lira, M. (2024). The influence of the tear film on the intraocular pressure and the corneal biomechanical properties analyzed with the Ocular Response Analyzer. Journal of Optometry, 17(2), 100488. https://doi.org/10.1016/j.optom.2023.100488
Vancouver
Da Silva F, Linhares JMM, Lira M. The influence of the tear film on the intraocular pressure and the corneal biomechanical properties analyzed with the Ocular Response Analyzer. Journal of Optometry. 2024;17(2):100488. doi:10.1016/j.optom.2023.100488
BibTeX
@article{DaSilva2024,
author = {Da Silva, Filipe and Linhares, João M M and Lira, Madalena},
title = {The influence of the tear film on the intraocular pressure and the corneal biomechanical properties analyzed with the Ocular Response Analyzer},
journal = {Journal of Optometry},
year = {2024},
volume = {17},
number = {2},
pages = {100488},
doi = {10.1016/j.optom.2023.100488}
}