EUVIMEDEUVIMED entdecken
Crossref

Environmental stabilization of perfect-crystal neutron interferometry using a large vacuum chamber with cryogenic sample access

R. Valdillez, D.G. Cory, R.W. Haun, B. Heacock, C. Heikes, S.F. Hoogerheide, M.G. Huber, T. Mineeva, J.W. Paster, D. Sarenac, D.A. Pushin, A.R. Young

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-12 · 1092 · 171845

DOI: 10.1016/j.nima.2026.171845 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-12. Verfasst von R. Valdillez und 11 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Canada First Research Excellence Fund, Canada Excellence Research Chairs, Government of Canada, Nuclear Physics.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room temperature and standard atmospheric pressure. However, neutron interferometry is sensitive to changes in the local environment, especially thermal gradients across the crystal, resulting in phase drifts and systematic uncertainty. A need for measurements performed in different sample environments compound these issues. Fortunately, the use of a vacuum chamber has been shown to be an effective method of environmental isolation for perfect-crystal neutron interferometers. A large volume, highly versatile vacuum chamber has been installed at the Neutron Interferometry and Optics Facility at the NIST Center for Neutron Research to isolate interferometry from local temperature and pressure deviations as well as allowing for the introduction of cryogenically cooled samples. The prospect of incorporating a cryostat within a neutron interferometer opens up new areas of investigation, such as superconductivity. In addition to describing the vacuum chamber, we report on the first measurement of a cryogenic-cooled sample by a neutron interferometer. For this demonstration contrast was measured with a Ni60Cu40 sample between 4 K to 300 K.

Förderung

  • Canada First Research Excellence Fund
  • Canada Excellence Research Chairs, Government of Canada
  • Nuclear Physics
  • U.S. Department of Energy
  • National Institute of Standards and Technology
  • Natural Sciences and Engineering Research Council of Canada
  • National Science Foundation

Zitieren

APA

Valdillez, R., Cory, D., Haun, R., Heacock, B., Heikes, C., Hoogerheide, S., Huber, M., Mineeva, T., Paster, J., Sarenac, D., Pushin, D., & Young, A. (2026). Environmental stabilization of perfect-crystal neutron interferometry using a large vacuum chamber with cryogenic sample access. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1092, 171845. https://doi.org/10.1016/j.nima.2026.171845

Vancouver

Valdillez R, Cory D, Haun R, Heacock B, Heikes C, Hoogerheide S, et al. Environmental stabilization of perfect-crystal neutron interferometry using a large vacuum chamber with cryogenic sample access. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1092:171845. doi:10.1016/j.nima.2026.171845

BibTeX
@article{Valdillez2026,
  author = {Valdillez, R. and Cory, D.G. and Haun, R.W. and Heacock, B. and Heikes, C. and Hoogerheide, S.F. and Huber, M.G. and Mineeva, T. and Paster, J.W. and Sarenac, D. and Pushin, D.A. and Young, A.R.},
  title = {Environmental stabilization of perfect-crystal neutron interferometry using a large vacuum chamber with cryogenic sample access},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2026},
  volume = {1092},
  pages = {171845},
  doi = {10.1016/j.nima.2026.171845}
}
Kostenlos starten →