A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-10 · 1090 · 171680
DOI: 10.1016/j.nima.2026.171680 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-10. Verfasst von Jiajin Ge und 8 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Society of Physics Students, US Department of Energy.
Abstract (Originalsprache)
Cluster counting dN/dx is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good pion-kaon separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable dN/dx measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/sqrt(Hz), surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the dN/dx method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC4H10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.
Förderung
- Society of Physics Students
- US Department of Energy
Zitieren
APA
Ge, J., Li, C., Suslu, C., Guo, Y., Salzer, E., Dai, T., Qian, J., Zhou, B., & Zhu, J. (2026). A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1090, 171680. https://doi.org/10.1016/j.nima.2026.171680
Vancouver
Ge J, Li C, Suslu C, Guo Y, Salzer E, Dai T, et al. A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1090:171680. doi:10.1016/j.nima.2026.171680
BibTeX
@article{Ge2026,
author = {Ge, Jiajin and Li, Chihao and Suslu, Can and Guo, Yuxiang and Salzer, Emmett and Dai, Tiesheng and Qian, Jianming and Zhou, Bing and Zhu, Junjie},
title = {A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2026},
volume = {1090},
pages = {171680},
doi = {10.1016/j.nima.2026.171680}
}
EUVIMED