Integration and characterization of readout electronics system for dN/dx measurement with drift chamber prototype
Radiation Detection Technology and Methods · 20.06.2026
DOI: 10.1007/s41605-026-00712-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Detection Technology and Methods, online erschienen am 20.06.2026. Verfasst von Dongcheng Cai und 12 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
To explore the feasibility of high-precision particle identification using the cluster counting technique for the drift chamber, a dedicated readout electronics system with low noise, high bandwidth, and high sampling rate is required. This paper presents the design and performance evaluation of a scalable readout prototype developed for this application. The system architecture integrates a custom front-end with a $1.3\ \text{GSps}$ waveform sampling backend, implemented within a modular 120-channel framework. Laboratory characterization of the 40-channel prototype demonstrates a $-3$ dB analog bandwidth of $460\ \text{MHz}$ and an Equivalent Noise Input current of $0.81\ \mu\text{A}_\text{rms}$. These specifications are essential for preserving the fast temporal features of ionization signals. Furthermore, the system achieves an intrinsic timing jitter of $0.87\ \text{ns}$, which satisfies the timing precision requirements for drift distance measurement. Joint experiments with a drift chamber prototype using cosmic rays verified the system's capability to resolve discrete ionization peaks within piled-up waveforms. These results confirm that the readout electronics provide the signal fidelity and temporal resolution necessary for future cluster counting algorithm development.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
- Guangdong Provincial Key Laboratory of Advanced Particle Detection Technology
Zitieren
APA
Cai, D., Li, Q., Dong, M., Gong, W., Ji, M., Liu, H., Pan, W., Wu, L., Xu, D., Yuan, Y., Zhang, H., Zhao, G., & Zhao, Y. (2026). Integration and characterization of readout electronics system for dN/dx measurement with drift chamber prototype. Radiation Detection Technology and Methods. https://doi.org/10.1007/s41605-026-00712-2
Vancouver
Cai D, Li Q, Dong M, Gong W, Ji M, Liu H, et al. Integration and characterization of readout electronics system for dN/dx measurement with drift chamber prototype. Radiation Detection Technology and Methods. 2026. doi:10.1007/s41605-026-00712-2
BibTeX
@article{Cai2026,
author = {Cai, Dongcheng and Li, Qicai and Dong, Mingyi and Gong, Weile and Ji, Mengyang and Liu, Hongbin and Pan, Wenyu and Wu, Linghui and Xu, Dewei and Yuan, Yimie and Zhang, Hongyu and Zhao, Guang and Zhao, Yubin},
title = {Integration and characterization of readout electronics system for dN/dx measurement with drift chamber prototype},
journal = {Radiation Detection Technology and Methods},
year = {2026},
doi = {10.1007/s41605-026-00712-2}
}
EUVIMED