Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024-04. Verfasst von Seungeun Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Applied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, United States. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health.
Abstract (Originalsprache)
External optical crosstalk remains a significant source of correlated noise in scintillation detectors optically coupled to silicon photomultiplier (SiPM) arrays and can influence achievable performance by limiting the maximum overvoltage at which a detector can be operated. This study evaluated the potential benefits of incorporating an optical bandpass filter, which is absorptive to optical crosstalk and transmissive for scintillation photons, between the scintillator and SiPM array. Several SiPM and bandpass configurations were characterized, including single-element and SiPM arrays with bare, filter-coupled, crystal-coupled, and crystal-filter-coupled interfaces. Coupling the optical filter between a 4 × 4 array of Broadcom AFBR-S4N44P164 M (NUV-MT) SiPMs and a 12 × 12 × 20 mm3 LYSO crystal decreased the total number of detected optical photon noise by up to 92%. The impact of the filter on crosstalk probability reduction was also characterized by the single-channel measurements with the same SiPM, suppressing external crosstalk up to 64%. With the filter coupled, SiPMs were operable at very high overvoltage. The results of these studies demonstrate that optical filtering is a promising technique to significantly reduce correlated noise in scintillation detectors employing SiPMs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Applied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, United States.
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health
Zitieren
APA
Lee, S., Choong, W. S., & Cates, J. W. (2024). Characterization of external optical crosstalk reduction for SiPM-based scintillation detectors with an optical bandpass filter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1061, 169101. https://doi.org/10.1016/j.nima.2024.169101
Vancouver
Lee S, Choong WS, Cates JW. Characterization of external optical crosstalk reduction for SiPM-based scintillation detectors with an optical bandpass filter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2024;1061:169101. doi:10.1016/j.nima.2024.169101
BibTeX
@article{Lee2024,
author = {Lee, Seungeun and Choong, Woon-Seng and Cates, Joshua William},
title = {Characterization of external optical crosstalk reduction for SiPM-based scintillation detectors with an optical bandpass filter},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2024},
volume = {1061},
pages = {169101},
doi = {10.1016/j.nima.2024.169101}
}
EUVIMED