EUVIMEDEUVIMED entdecken
Open Access

PET Detectors Based on Multi-Resolution SiPM Arrays

Jiahao Xie, Haibo Wang, Simon R Cherry, Junwei Du

IEEE Transactions on Radiation and Plasma Medical Sciences · 2024-05 · 8 (5) · 493-500

DOI: 10.1109/trpms.2024.3381865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2024-05. Verfasst von Jiahao Xie und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Almost all high spatial resolution positron emission tomography (PET) detectors based on pixelated scintillator arrays utilize crystal arrays with smaller pitches than photodetector arrays, leading to challenges in resolving edge crystals. To address this issue, this paper introduces a novel multi-resolution silicon photomultiplier (SiPM) array design aimed at decreasing the number of readout channels required while maintaining the crystal resolvability of the detector, especially for edge crystals. The performance of a pseudo 9 × 9 multi-resolution SiPM array, consisting of 6.47 × 6.47 mm2, 6.47 × 3.07 mm2, and 3.07 × 3.07 mm2 SiPMs, was compared to those of a pseudo 8 × 8 SiPM array with a 6.8 mm pitch, and a 16 × 16 SiPM array with a 3.4 mm pitch using a 36 × 36 LYSO array with a pitch of 1.5 mm. The large-size pseudo SiPMs were implemented by digitally grouping multiple 3.07 × 3.07 mm2 SiPMs. The flood histograms show that the edge crystal resolvability of the pseudo 9 × 9 multi-resolution SiPM array is comparable to that of the 16 × 16 SiPM array and is significantly better than that of the 8 × 8 SiPM array.

Schlagwörter

Stichwörter der Autor:innen

PETRadiation DetectorSiPM

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Xie, J., Wang, H., Cherry, S. R., & Du, J. (2024). PET Detectors Based on Multi-Resolution SiPM Arrays. IEEE Transactions on Radiation and Plasma Medical Sciences, 8(5), 493-500. https://doi.org/10.1109/trpms.2024.3381865

Vancouver

Xie J, Wang H, Cherry SR, Du J. PET Detectors Based on Multi-Resolution SiPM Arrays. IEEE Transactions on Radiation and Plasma Medical Sciences. 2024;8(5):493-500. doi:10.1109/trpms.2024.3381865

BibTeX
@article{Xie2024,
  author = {Xie, Jiahao and Wang, Haibo and Cherry, Simon R and Du, Junwei},
  title = {PET Detectors Based on Multi-Resolution SiPM Arrays},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2024},
  volume = {8},
  number = {5},
  pages = {493--500},
  doi = {10.1109/trpms.2024.3381865}
}
Kostenlos starten →