EUVIMEDEUVIMED entdecken
Crossref

A large area, high counting rate micromegas-based neutron detector for BNCT

Zhujun Fang, Zhiyong Zhang, Bin Shi, Wei Jiang, Xianke Liu, Siqi He, Jun Chen, Ping Cao, Jianbei Liu, Yi Zhou, Ming Shao, Botian Qu und 2 weitere

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2023-08 · 1053 · 168361

DOI: 10.1016/j.nima.2023.168361 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023-08. Verfasst von Zhujun Fang und 13 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of the detectors used in BNCT only have a small detection area, leading to the inconvenience of the full-scale 2-D measurement of the beam. Based on micromegas technology, we designed a neutron detector with large detection area and high counting rate. This detector has a detection area of 288 mm multiples 288 mm and can measure thermal, epithermal, and fast neutrons with different detector settings. The BNCT experiments demonstrated that this detector has a very good 2-D imaging performance for the thermal, epithermal, fast neutron and gamma components, a highest counting rate of 94 kHz/channel, and a good linearity response to the beam power. Additionally, the flux fraction of each component can be calculated based on the measurement results. The Am-Be neutron source experiment indicates that this detector has a spatial resolution of approximately 1.4 mm, meeting the requirements of applications in BNCT. It is evident that this micromegas-based neutron detector with a large area and high counting rate capability has great development prospects in BNCT beam monitoring and evaluation applications.

Zitieren

APA

Fang, Z., Zhang, Z., Shi, B., Jiang, W., Liu, X., He, S., Chen, J., Cao, P., Liu, J., Zhou, Y., Shao, M., Qu, B., Zhang, S., & Wang, Q. (2023). A large area, high counting rate micromegas-based neutron detector for BNCT. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1053, 168361. https://doi.org/10.1016/j.nima.2023.168361

Vancouver

Fang Z, Zhang Z, Shi B, Jiang W, Liu X, He S, et al. A large area, high counting rate micromegas-based neutron detector for BNCT. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2023;1053:168361. doi:10.1016/j.nima.2023.168361

BibTeX
@article{Fang2023,
  author = {Fang, Zhujun and Zhang, Zhiyong and Shi, Bin and Jiang, Wei and Liu, Xianke and He, Siqi and Chen, Jun and Cao, Ping and Liu, Jianbei and Zhou, Yi and Shao, Ming and Qu, Botian and Zhang, Shufeng and Wang, Qian},
  title = {A large area, high counting rate micromegas-based neutron detector for BNCT},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2023},
  volume = {1053},
  pages = {168361},
  doi = {10.1016/j.nima.2023.168361}
}
Kostenlos starten →