Comparison and precision of visceral adipose tissue measurement techniques in a multisite longitudinal study using MRI
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.07.002 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Samuel Barnes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Loma Linda University School of Medicine, Loma Linda, CA, United States of America. Electronic address: sabarnes@llu.edu. Hauptthemen laut MEDLINE: Intra-Abdominal Fat, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hass Avacado Board.
Abstract (Originalsprache)
BACKGROUND: Measurement of visceral adipose tissue (VAT) using magnetic resonance imaging (MRI) is considered accurate and safe. Single slice measurements perform similar to volumetric measurements for cross-sectional observation studies but may not perform as well for longitudinal studies. This study compared the performance of single slice to volumetric VAT measurements in a prospective longitudinal study. Consistency of results across sites and over time was also evaluated. METHODS: A total of 935 healthy participants were recruited and scanned with MRI twice, approximately six months apart as part of a randomized, controlled, parallel arm, unblinded study conducted at four clinical centers in the United States. A 3D Dixon MRI sequence was used to image the abdomen, and visceral fat volumes were quantified for the abdomen, reduced coverage volumes (11 and 25 slices), and at single slices positioned at anatomical landmarks. A traveling phantom was scanned twice at all imaging sites. RESULTS: The correlation of single slice VAT measurement to full abdomen volumetric measurements ranged from 0.78 to 0.93 for cross-sectional observation measurements and 0.30 to 0.55 for longitudinal change. Reduced coverage volumetric measurement outperformed single slice measurements but still showed improved precision with more slices with cross-sectional observation and longitudinal correlations of 0.94 and 0.66 for 11 slices and 0.94 and 0.70 for 25 slices, respectively. No significant differences were observed across sites or over time with the traveling phantom and the volume measurements had a standard deviation of 14.1 mL, 2.6% of the measured volume. CONCLUSION: Single slice VAT measurements had significantly lower correlation with abdomen VAT volume for longitudinal change than for cross-sectional observation measurements and may not be suitable for longitudinal studies. Data from multiple sites, different scanners, and over time did not show significant differences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Loma Linda University School of Medicine, Loma Linda, CA, United States of America. Electronic address: sabarnes@llu.edu.
- Department of Radiology, Loma Linda University School of Medicine, Loma Linda, CA, United States of America.
- Department of Psychology, Loma Linda University School of Behavioral Health, Loma Linda, CA, United States of America.
- Center for Nutrition, Lifestyle and Disease Prevention, Loma Linda University School of Public Health, Loma Linda, CA, United States of America.
Förderung
- Hass Avacado Board
Zitieren
APA
Barnes, S., Kinne, E., Chowdhury, S., Loong, S., Moretz, J., & Sabate, J. (2024). Comparison and precision of visceral adipose tissue measurement techniques in a multisite longitudinal study using MRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.07.002
Vancouver
Barnes S, Kinne E, Chowdhury S, Loong S, Moretz J, Sabate J. Comparison and precision of visceral adipose tissue measurement techniques in a multisite longitudinal study using MRI. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.07.002
BibTeX
@article{Barnes2024,
author = {Barnes, Samuel and Kinne, Erica and Chowdhury, Shilpy and Loong, Spencer and Moretz, Jeremy and Sabate, Joan},
title = {Comparison and precision of visceral adipose tissue measurement techniques in a multisite longitudinal study using MRI},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.07.002}
}
EUVIMED