EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Unravelling the mechanisms of CE-SSFP in imaging myocardium at risk: The effect of relaxation times on myocardial contrast

Christos G Xanthis, Robert Jablonowski, Sebastian Bidhult-Johansson, David Nordlund, Anna-Bettina Haidich, Tania Lala, Håkan Arheden, Anthony H Aletras

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.03.043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Christos G Xanthis und 7 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden; Laboratory of Computing, Medical…. Hauptthemen laut MEDLINE: Contrast Media, Myocardial Infarction. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Region Skåne, Lund University Faculty of Medicine, Hjärt-Lungfonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The aim of this study was to investigate the contrast mechanisms of Contrast-enhanced steady-state free-precession (CE-SSFP) through the utilization of Bloch simulations in an experimental porcine model and in patients with acute myocardial infarction. METHODS: Six pigs and ten patients with myocardial infarction underwent CMR and tissue characterization at 1.5 T whereas a Bloch simulation framework was utilized to simulate the CE-SSFP signal formation and compare it against the actual CE-SSFP signal acquired from the experimental porcine model and the patient population. The relaxation times of remote, salvaged, and infarcted myocardium were calculated after the injection of gadolinium, at the time of CE-SSFP acquisition. Simulations were performed using the same CE-SSFP pulse sequence as used on the scanner on a set of spins with the calculated relaxation times from the CMR scans. RESULTS: The normalized signal intensities of salvaged and infarcted myocardium obtained with simulations were lower than the corresponding normalized signal intensities obtained in vivo in pigs (p < 0.05, 134% vs 153%) and in patients (p < 0.05, 126% vs 145%). The results from simulations showed a linear relationship to the results obtained in the experimental porcine model (r2 = 0.61) and in patients (r2 = 0.69). CONCLUSION: The T1 and T2 values of remote, salvaged, and infarcted myocardium only partly explain the signal intensities in CE-SSFP images. Bloch simulations suggest that there may be more elements that contribute to the CE-SSFP contrast. Integration of other aspects of the MR experiment into the simulation model could further help to fully unravel the mechanisms of CE-SSFP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaMyocardial InfarctionAnimalsSwineHumansMiddle AgedFemaleMaleMagnetic Resonance ImagingComputer SimulationMyocardiumAgedImage Interpretation, Computer-AssistedImage EnhancementReproducibility of Results

Stichwörter der Autor:innen

CE-SSFPMyocardium at riskSimulations

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden; Laboratory of Computing, Medical Informatics and Biomedical - Imaging Technologies, School of Medicine…
  • Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
  • Laboratory of Hygiene, Social-Preventive Medicine and Medical Statistics, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, University Campus, 54124 Thessaloniki, Greece.
  • Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden; Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden.

Förderung

  • Region Skåne
  • Lund University Faculty of Medicine
  • Hjärt-Lungfonden
  • Skånes universitetssjukhus

Zitieren

APA

Xanthis, C. G., Jablonowski, R., Bidhult-Johansson, S., Nordlund, D., Haidich, A. B., Lala, T., Arheden, H., & Aletras, A. H. (2024). Unravelling the mechanisms of CE-SSFP in imaging myocardium at risk: The effect of relaxation times on myocardial contrast. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.03.043

Vancouver

Xanthis CG, Jablonowski R, Bidhult-Johansson S, Nordlund D, Haidich AB, Lala T, et al. Unravelling the mechanisms of CE-SSFP in imaging myocardium at risk: The effect of relaxation times on myocardial contrast. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.03.043

BibTeX
@article{Xanthis2024,
  author = {Xanthis, Christos G and Jablonowski, Robert and Bidhult-Johansson, Sebastian and Nordlund, David and Haidich, Anna-Bettina and Lala, Tania and Arheden, Håkan and Aletras, Anthony H},
  title = {Unravelling the mechanisms of CE-SSFP in imaging myocardium at risk: The effect of relaxation times on myocardial contrast},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.03.043}
}
Kostenlos starten →