Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.02.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Daiki Ito und 5 weiteren Autor:innen. Beteiligte Einrichtung: Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan; Department of Radiological Sciences, …. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Keio University.
Abstract (Originalsprache)
Three-dimensional (3D) magnetic resonance elastography (MRE) is more accurate than two-dimensional (2D) MRE; however, it requires long-term acquisition. This study aimed to reduce the acquisition time of abdominal 3D MRE using a new sample interval modulation (short-SLIM) approach that can acquire all three motions faster while reducing the prolongation of echo time and flow compensation. To this end, two types of phantom studies and an in vivo test of the liver in three healthy volunteers were performed to compare the performances of conventional spin-echo echo-planar (SE-EPI) MRE, conventional SLIM and short-SLIM. One phantom study measured the mean amplitude and shear modulus within the overall region of a homogeneous phantom by changing the mechanical vibration power to assess the robustness to the lowered phase-to-noise ratio in short-SLIM. The other measured the mean shear modulus in the stiff and background materials of a phantom with an embedded stiffer rod to assess the performance of short-SLIM for complex wave patterns with wave interference. The Spearman's rank correlation coefficient was used to assess similarity of elastograms in the rod-embedded phantom and liver between methods. The results of the phantom study changing the vibration power indicated that there was little difference between conventional MRE and short-SLIM. Moreover, the elastogram pattern and the mean shear modulus in the rod-embedded phantom in conventional SLIM and short-SLIM did not change for conventional MRE; the liver test also showed a small difference between the acquisition techniques. This study demonstrates that short-SLIM can provide MRE results comparable to those of conventional MRE. Short-SLIM can reduce the total acquisition time by a factor of 2.25 compared to conventional 3D MRE time, leading to an improvement in the accuracy of shear modulus estimation by suppressing the patient movements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan Universit…
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan; Health Research Institute, National Institute of Advan…
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
- Department of Diagnostic Radiology, National Tokyo Medical Center, 2-5-1, Higashigaoka, Meguro-ku, Tokyo 152-8902, Japan; Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo…
- Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Förderung
- Japan Society for the Promotion of Science
- Keio University
Zitieren
APA
Ito, D., Numano, T., Habe, T., Okuda, S., Nozaki, T., & Jinzaki, M. (2024). Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.02.009
Vancouver
Ito D, Numano T, Habe T, Okuda S, Nozaki T, Jinzaki M. Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.02.009
BibTeX
@article{Ito2024,
author = {Ito, Daiki and Numano, Tomokazu and Habe, Tetsushi and Okuda, Shigeo and Nozaki, Taiki and Jinzaki, Masahiro},
title = {Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.02.009}
}
EUVIMED