Fast T2 mapping of short-T2 tissues in knee using 3D radial dual-echo balanced steady-state free precession

Bowen Li, Zekang Ding, Huajun She

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.01.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Bowen Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Patellar Ligament. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: T2 mapping of short-T2 tissues in the knee (meniscus, tendon, and ligament) is needed to aid the clinical MRI knee diagnosis, which is hard to realize using traditional clinical methods. PURPOSE: To accelerate the acquisition of T2 values for short-T2 tissues in the knee by analyzing the signal equation of balanced steady-state free precession (bSSFP) sequence in MRI. METHODS: Effect of half-radial acquisition on pixel bandwidth was analyzed mathematically. A modified 3D radial dual-echo bSSFP sequence was proposed for 0.53 mm isotropic resolution knee imaging with 2 different TEs at 3 T, which alleviated the problem of off-resonance artifacts caused by traditional half-radial acquisition scheme. A novel pixel-based optimization method was proposed for efficient T2 mapping of short-T2 tissues in the knee given off-resonance values. Simulation was conducted to evaluate the sensitivity of the proposed method to other parameters. Phantom results were compared with 2D spin-echo (SE), and in vivo results were compared with SE and previously studies. RESULTS: Simulation showed that the proposed method is insensitive to T1 and B1 variations (estimation error < 1% for T1/B1 error of ±90%), avoiding the need for separated T1 and B1 scans. High isotropic resolution knee imaging was achieved using the modified dual-echo bSSFP. The total scan time was within 3.5 min, including a separate off-resonance scan for T2 measurement. Measured mean T2 values for phantoms correlated well with SE (R2 = 0.99), and no significant difference was observed (P = 0.45). In vivo meniscus T2 measurements and ligament T2 measurements agreed with the literature, while tendon T2 measurements were much lower (31.7% lower for patellar tendon, and 13.5% lower for quadriceps tendon), which might result in its bi-component property. CONCLUSIONS: The proposed method provides an efficient way for fast, robust, high-resolution imaging and T2 mapping of short-T2 tissues in the knee.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalPatellar LigamentHumansKnee JointKneeMagnetic Resonance ImagingPhantoms, Imaging

Stichwörter der Autor:innen

3D radialKneeShort-T(2) tissueT(2) mappingbSSFP

Autor:innen und Institutionen

  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Electronic address: shehuajun@hotmail.com.

Zitieren

APA

Li, B., Ding, Z., & She, H. (2024). Fast T2 mapping of short-T2 tissues in knee using 3D radial dual-echo balanced steady-state free precession. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.01.011

Vancouver

Li B, Ding Z, She H. Fast T2 mapping of short-T2 tissues in knee using 3D radial dual-echo balanced steady-state free precession. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.01.011

BibTeX
@article{Li2024,
  author = {Li, Bowen and Ding, Zekang and She, Huajun},
  title = {Fast T2 mapping of short-T2 tissues in knee using 3D radial dual-echo balanced steady-state free precession},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.01.011}
}
Kostenlos starten →