An activatable chemiluminescent probe for selective and portable quantification of copper ions in food and environmental samples
Microchemical Journal · 2026-06 · 225 · 118021
DOI: 10.1016/j.microc.2026.118021 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchemical Journal, 2026-06. Verfasst von Yue Wang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Copper ion (Cu 2+ ) quantification in complex food and environmental matrices remains challenging because of matrix interference and the need for rapid, portable analysis. Herein, we report ACL-Cu, an activatable chemiluminescent 1,2-dioxetane probe for selective Cu 2+ detection. Under mildly alkaline conditions (pH 8.0), Cu 2+ triggers intramolecular cyclization of ACL-Cu, producing green chemiluminescence centered at ∼550 nm with an approximately 26-fold signal enhancement relative to the probe alone. ACL-Cu showed high selectivity toward Cu 2+ over common metal ions and anions, and quantitative analysis on the IVIS platform gave a linear response over 0.2–3.0 μM with a limit of detection of 43 nM. A handheld portable device also enabled Cu 2+ quantification over the same linear range, with a detection limit of 76 nM and an assay time of ≤10 min. In porcine liver and lake water samples spiked prior to pretreatment, ACL-Cu provided concentration-dependent responses and accurate quantification, affording recoveries of 91.7–97.0% for IVIS and 90.0–96.0% for portable device, with relative standard deviations below 2.35%. These results demonstrate that ACL-Cu is a reliable chemiluminescent platform for Cu 2+ determination in complex real samples and holds promise for food safety and environmental monitoring.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, Y., Huang, S., Wang, W., Zhang, J., Bu, L., & Li, J. (2026). An activatable chemiluminescent probe for selective and portable quantification of copper ions in food and environmental samples. Microchemical Journal, 225, 118021. https://doi.org/10.1016/j.microc.2026.118021
Vancouver
Wang Y, Huang S, Wang W, Zhang J, Bu L, Li J. An activatable chemiluminescent probe for selective and portable quantification of copper ions in food and environmental samples. Microchemical Journal. 2026;225:118021. doi:10.1016/j.microc.2026.118021
BibTeX
@article{Wang2026,
author = {Wang, Yue and Huang, Shengjie and Wang, Wenjing and Zhang, Jiaheng and Bu, Lingli and Li, Jun},
title = {An activatable chemiluminescent probe for selective and portable quantification of copper ions in food and environmental samples},
journal = {Microchemical Journal},
year = {2026},
volume = {225},
pages = {118021},
doi = {10.1016/j.microc.2026.118021}
}
EUVIMED