A closed-form expression for the relationship between shear modulus from shear wave elastography and tangent modulus from tensile test
Medical Engineering & Physics · 2025
DOI: 10.1016/j.medengphy.2025.104387 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Engineering & Physics, 2025. Verfasst von Luiz Carlos da Silva Nunes und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering Department, Fluminense Federal University (UFF), Niteroi-RJ, Brazil. Electronic address: luizcsn@id.uff.br. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Tensile Strength, Shear Strength, Elastic Modulus. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Financiadora de Estudos e Projetos, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
Although shear wave elastography has been increasingly employed for in-vivo studies of the mechanical properties of human tendons, critical questions have emerged regarding the correlation between acoustic measurements and the shear modulus determined from mechanical testing. This study proposes a closed-form expression for estimating the tangent modulus of tendons under tension. This expression is formulated as a function of the shear modulus and is obtained by combining identifications on both tensile testing and elastography measurements. A one-dimensional nonlinear model is employed for tensile test data, accounting for the strain behavior of tendon fiber bundles as a function of stress and four identifiable parameters. This model describes the entire physiological range, including the tendon in its crimped state. A new model based on empirical observations defines the shear modulus response obtained from elastography in terms of tensile stress. By combining these models, the closed-form expression was derived. Stress-strain data obtained from tensile tests and shear modulus measurements from shear wave elastography of eleven in vitro samples of fresh-frozen human Achilles tendons, experimentally obtained, were reanalyzed. The proposed methodology reduces high-frequency noise in the stress-strain data, producing tangent-modulus estimates less sensitive to numerical differentiation. This approach is also practical in scenarios where tendons are crimped, or fibers are fully extended, providing estimations of material properties that combine potentially in-vivo SSI elastography with a tendon material constitutive model.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical Engineering Department, Fluminense Federal University (UFF), Niteroi-RJ, Brazil. Electronic address: luizcsn@id.uff.br.
- Biomedical Engineering Program, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro-RJ, Brazil. Electronic address: liliam@peb.ufrj.br.
- Biomedical Engineering Program, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro-RJ, Brazil. Electronic address: mclara@peb.ufrj.br.
- Biomedical Engineering Program, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro-RJ, Brazil. Electronic address: lmeneg@peb.ufrj.br.
Förderung
- Financiadora de Estudos e Projetos
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
Zitieren
APA
Nunes, L. C. D. S., de Oliveira, L. F., Brandão, M. C. A., & Menegaldo, L. L. (2025). A closed-form expression for the relationship between shear modulus from shear wave elastography and tangent modulus from tensile test. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2025.104387
Vancouver
Nunes LCDS, de Oliveira LF, Brandão MCA, Menegaldo LL. A closed-form expression for the relationship between shear modulus from shear wave elastography and tangent modulus from tensile test. Medical Engineering & Physics. 2025. doi:10.1016/j.medengphy.2025.104387
BibTeX
@article{Nunes2025,
author = {Nunes, Luiz Carlos da Silva and de Oliveira, Liliam Fernandes and Brandão, Maria Clara Albuquerque and Menegaldo, Luciano Luporini},
title = {A closed-form expression for the relationship between shear modulus from shear wave elastography and tangent modulus from tensile test},
journal = {Medical Engineering & Physics},
year = {2025},
doi = {10.1016/j.medengphy.2025.104387}
}
EUVIMED