EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Whole-cycle and time-specific validation of a GUI-based ground reaction force estimation tool for clinical gait analysis without a force plate

Pegah Jamali, Li-Shan Chou, Robert D Catena

Medical Engineering & Physics · 2025

DOI: 10.1016/j.medengphy.2025.104366 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Medical Engineering & Physics, 2025. Verfasst von Pegah Jamali und 2 weiteren Autor:innen. Beteiligte Einrichtung: Washington State University, Pullman, Washington, 99164-1410, USA. Hauptthemen laut MEDLINE: Gait Analysis, Mechanical Phenomena, Gait. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 85 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Oregon, American Society of Biomechanics.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Relying on patients to make clean contacts with multiple force plates during clinical gait analysis can be time-consuming and dissuade clinicians from collecting biomechanical data. Several methods have been proposed to estimate ground reaction forces (GRFs) without force plates, though many can be computationally intensive. As an alternative to measuring GRFs, we evaluated the whole cycle and time frame accuracy of a built-in, GUI-based GRF estimation tool. Twenty-seven healthy adult participants walked over two consecutive force plates. We evaluated the accuracy of estimated GRFs against force plates as the gold standard using correlation, residual error analysis, and statistical parametric mapping (SPM). Estimated GRF magnitudes were accurate in the anterior-posterior (R2=0.86, %RMSE=7.28), and vertical directions (R2=0.86, %RMSE=6.09), but not in the medio-lateral direction (R2=0.30, %RMSE=12.46). SPM revealed errors in the sagittal plane in mid- and late-stance, with no specific errors in the medio-lateral direction. Estimated centers of pressure (CoPs) showed good accuracy (R2≥0.99, %RMSE≤4.46). However, SPM showed estimated CoPs were consistently anterior to the true CoPs. Sagittal GRFs are predicted with good accuracy, showing whole cycle errors comparable to more complex methods, while also displaying little early stance error and offering user-friendly implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gait AnalysisMechanical PhenomenaGaitHumansMaleFemaleAdultBiomechanical PhenomenaTime FactorsYoung Adult

Stichwörter der Autor:innen

AccuracyCenter of pressureGround contact forceStatistical parametric mapping

Autor:innen und Institutionen

  • Washington State University, Pullman, Washington, 99164-1410, USA.
  • Iowa State University, Ames, Iowa, 50011-4008, USA.
  • Washington State University, Pullman, Washington, 99164-1410, USA. Electronic address: robert.catena@wsu.edu.

Förderung

  • University of Oregon
  • American Society of Biomechanics

Zitieren

APA

Jamali, P., Chou, L. S., & Catena, R. D. (2025). Whole-cycle and time-specific validation of a GUI-based ground reaction force estimation tool for clinical gait analysis without a force plate. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2025.104366

Vancouver

Jamali P, Chou LS, Catena RD. Whole-cycle and time-specific validation of a GUI-based ground reaction force estimation tool for clinical gait analysis without a force plate. Medical Engineering & Physics. 2025. doi:10.1016/j.medengphy.2025.104366

BibTeX
@article{Jamali2025,
  author = {Jamali, Pegah and Chou, Li-Shan and Catena, Robert D},
  title = {Whole-cycle and time-specific validation of a GUI-based ground reaction force estimation tool for clinical gait analysis without a force plate},
  journal = {Medical Engineering & Physics},
  year = {2025},
  doi = {10.1016/j.medengphy.2025.104366}
}
Kostenlos starten →