EUVIMEDEUVIMED entdecken
Crossref

Tailoring left ventricular assist device cannula implantation using coupled multi-scale multi-objective optimization

Abubakar Dankano, Ray Prather, Blake Lozinski, Eduardo Divo, Alain Kassab, William DeCampli

Medical Engineering & Physics · 2024

DOI: 10.1016/j.medengphy.2024.104124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Engineering & Physics, 2024. Verfasst von Abubakar Dankano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL 32816, United States. Elect…. Hauptthemen laut MEDLINE: Heart-Assist Devices, Thrombosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: American Heart Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The frequent occurrence of thromboembolic cerebral events continues to limit the widespread implementation of Ventricular Assist Devices (VAD) despite continued advancements in VAD design and anti-coagulation treatments. Recent studies point to the optimal positioning of the outflow graft (OG) as a potential mitigator of post implantation thromboembolism. OBJECTIVE: This study aims to examine the tailoring of the OG implantation orientation with the goal of minimizing the number of thrombi reaching the cerebral vessels by means of a formal shape optimization scheme incorporated into a multi-scale hemodynamics analysis. METHODS: A 3-D patient-specific computational fluid dynamics model is loosely coupled in a two-way manner to a 0-D lumped parameter model of the peripheral circulation. A Lagrangian particle-tracking scheme models and tracks thrombi as non-interacting solid spheres. The loose coupling between CFD and LPM is integrated into a geometric shape optimization scheme which aims to optimize an objective function that targets a drop in cerebral embolization, and an overall reduction in particle residence times. RESULTS: The results elucidate the importance of OG anastomosis orientation and placement particularly in the case that studied particle release from the OG, as a fivefold decrease in cerebral embolization was observed between the optimal and non-optimal implantations. Another case considered particle release from the ventricle and aortic root walls, in which optimal implantation was achieved with a shallow insertion angle. Particle release from all three origins was investigated in the third case, demonstrating that the optimal configurations were generally characterized by VAD flow directed along the central lumen of the aortic arch. Because optimal configurations depended on the anatomic origin of the thrombus, it is important to determine, in clinical studies, the most likely sites of thrombus formation in VAD patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesThrombosisHumansCannulaAortaAorta, ThoracicHemodynamicsModels, Cardiovascular

Stichwörter der Autor:innen

CFDHeart FailureHemodynamicsLVADMulti-scalePareto optimization

Autor:innen und Institutionen

  • Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL 32816, United States. Electronic address: aad_abu@knights.ucf.edu.
  • Arnold Palmer Children's Hospital, 92 West Miller St, Orlando, FL 32806, United States.
  • Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL 32816, United States.
  • Department of Mechanical Engineering, Embry-Riddle Aeronautical University, 600 South Clyde Morris Blvd, Daytona Beach, FL 32114, United States.
  • College of Medicine, University of Central Florida, Arnold Palmer Children's Hospital, 92 West Miller St, Orlando, FL 32806, United States.

Förderung

  • American Heart Association

Zitieren

APA

Dankano, A., Prather, R., Lozinski, B., Divo, E., Kassab, A., & DeCampli, W. (2024). Tailoring left ventricular assist device cannula implantation using coupled multi-scale multi-objective optimization. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2024.104124

Vancouver

Dankano A, Prather R, Lozinski B, Divo E, Kassab A, DeCampli W. Tailoring left ventricular assist device cannula implantation using coupled multi-scale multi-objective optimization. Medical Engineering & Physics. 2024. doi:10.1016/j.medengphy.2024.104124

BibTeX
@article{Dankano2024,
  author = {Dankano, Abubakar and Prather, Ray and Lozinski, Blake and Divo, Eduardo and Kassab, Alain and DeCampli, William},
  title = {Tailoring left ventricular assist device cannula implantation using coupled multi-scale multi-objective optimization},
  journal = {Medical Engineering & Physics},
  year = {2024},
  doi = {10.1016/j.medengphy.2024.104124}
}
Kostenlos starten →