EUVIMEDEUVIMED entdecken
Crossref

Adequate canal-filling ratio and extension stem length reduce radiographic loosening in revision total knee arthroplasty using hybrid fixation with grit-blasted, fluted stems

Po-Wei Shao, Yu-Chih Lin, Chun-Ting Chu, Chih-Hsiang Chang, Chih-Chien Hu, Tung-Wu Lu, Sheng-Hsun Lee

The Knee · 2026-10 · 62 · 104508

DOI: 10.1016/j.knee.2026.104508 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Knee, 2026-10. Verfasst von Po-Wei Shao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Chang Gung University, Taoyuan 33302, Taiwan. Electronic address: Subway0102@gmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Prosthesis Failure, Knee Prosthesis. Die Arbeit nennt 47 Literaturangaben. Gefördert von: Chang Gung Memorial Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The extension stem plays a critical role in ensuring mechanical stability during revision total knee arthroplasty (RTKA). We hypothesized that higher canal-filling ratios (CFR) and sufficient extension stem lengths are associated with reduced radiographic loosening. This study aimed to test this hypothesis in revision total knee arthroplasty (RTKA) using hybrid fixation and to determine the optimal cutoff values. METHODS: We retrospectively analyzed patients undergoing RTKA from 2002 to 2020. Inclusion criteria were minor bone defects, revision for aseptic reasons or reimplantation after infection eradication, hybrid fixation, implantation with the U2 PSA™ Knee System (United Orthopedics ®, Taiwan), and ≥24-month follow-up. Prosthesis loosening was radiographically defined using the modified Knee Society scoring system. Receiver operating characteristic curve analysis was used to determine cutoff values for the CFR and stem length related to prosthesis loosening. Univariate logistic regression analysis was used to assess the relationship between CFR-related parameters and prosthesis loosening. RESULTS: Radiographic loosening occurred in 21 out of 79 cases. Demographics did not differ between loosening and non-loosening groups. Univariate logistic regression analysis identified protective factors against loosening, including a femoral CFR ≥ 0.83 with a stem length ≥20.7 mm, and a tibial CFR ≥ 0.77 with a stem length ≥18.7 mm. CONCLUSION: To mitigate the risk of post-RTKA aseptic loosening using hybrid fixation, we recommend a target femoral CFR ≥ 0.83 with a stem length exceeding 20.7 mm and a tibial CFR ≥ 0.77 with a stem length exceeding 18.7 mm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeProsthesis FailureKnee ProsthesisHumansReoperationRetrospective StudiesProsthesis DesignFemaleMaleAgedMiddle AgedRadiography

Stichwörter der Autor:innen

Canal-filling ratioExtension stemRevision total knee arthroplasty

Autor:innen und Institutionen

  • Department of Medicine, Chang Gung University, Taoyuan 33302, Taiwan. Electronic address: Subway0102@gmail.com.
  • Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan. Electronic address: b101092127@cgmh.org.tw.
  • Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan. Electronic address: rick910597@gmail.com.
  • Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan. Electronic address: ccc0810.chang@gmail.com.
  • Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan. Electronic address: r52906154@cgmh.org.tw.
  • Department of Biomedical Engineering, National Taiwan University, Taipei 10617, Taiwan. Electronic address: twlu@ntu.edu.tw.

Förderung

  • Chang Gung Memorial Hospital

Zitieren

APA

Shao, P. W., Lin, Y. C., Chu, C. T., Chang, C. H., Hu, C. C., Lu, T. W., & Lee, S. H. (2026). Adequate canal-filling ratio and extension stem length reduce radiographic loosening in revision total knee arthroplasty using hybrid fixation with grit-blasted, fluted stems. The Knee, 62, 104508. https://doi.org/10.1016/j.knee.2026.104508

Vancouver

Shao PW, Lin YC, Chu CT, Chang CH, Hu CC, Lu TW, et al. Adequate canal-filling ratio and extension stem length reduce radiographic loosening in revision total knee arthroplasty using hybrid fixation with grit-blasted, fluted stems. The Knee. 2026;62:104508. doi:10.1016/j.knee.2026.104508

BibTeX
@article{Shao2026,
  author = {Shao, Po-Wei and Lin, Yu-Chih and Chu, Chun-Ting and Chang, Chih-Hsiang and Hu, Chih-Chien and Lu, Tung-Wu and Lee, Sheng-Hsun},
  title = {Adequate canal-filling ratio and extension stem length reduce radiographic loosening in revision total knee arthroplasty using hybrid fixation with grit-blasted, fluted stems},
  journal = {The Knee},
  year = {2026},
  volume = {62},
  pages = {104508},
  doi = {10.1016/j.knee.2026.104508}
}
Kostenlos starten →