EUVIMEDEUVIMED entdecken
Vergleichsstudie

Biomechanical comparison of two extensor mechanism reconstruction techniques

John Moon, Camryn Pletka, Hugh Jones, Shuyang Han, Jonathan Gold, Sabir Ismaily, David Rodriguez

The Knee · 2026-08 · 61 · 104440

DOI: 10.1016/j.knee.2026.104440 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Knee, 2026-08. Verfasst von John Moon und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: J…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Surgical Mesh, Tibia, Plastic Surgery Procedures. Die Arbeit nennt 9 Literaturangaben. Gefördert von: University of Texas Health Science Center at Houston.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION Extensor mechanism disruption is a debilitating complication that can occur following total knee arthroplasty. High primary repair failure rates have made reconstruction the treatment of choice. The literature describes two methods of reconstruction with synthetic mesh, however these methods have not been biomechanically compared. METHODS Synthetic mesh constructs were implanted in six matched pairs of cadaveric tibiae using the tuberosity technique, where mesh is anchored at the tuberosity, and the intramedullary technique, where the mesh is cemented within the medullary canal underneath the tibial component. During biomechanical testing, joint reaction forces were applied to the tibial base plate while axial tensile loads were applied to the mesh construct to measure stiffness, yield force, and ultimate force to failure. Displacements of the tibial tray and the point of load were tracked using an infrared motion analysis system. RESULTS There were significant differences between the two constructs. Overall, the intramedullary technique was 3 times stiffer (107 ± 11 N/mm vs 42 ± 12 N/mm, P = 0.03) and 54% stronger (1143 ± 31 N vs 741 ± 85 N, P = 0.03) than the trough technique. There was also an increased yield strength (729 ± 9 N vs 542 ± 78 N, P = 0.03). Failure of the trough method occurred at the mesh insertion site whereas failure of the intramedullary technique was between the insertion site and patellar level. CONCLUSIONS This study shows a potential biomechanical advantage when implanting under the tibial base plate. While our model does not incorporate soft tissue ingrowth, it does compare insertion techniques where ingrowth has minimal effects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeSurgical MeshTibiaPlastic Surgery ProceduresHumansBiomechanical PhenomenaCadaverAgedFemaleMale

Stichwörter der Autor:innen

Extensor reconstructionPatellar tendonPolypropylene mesh reconstructionQuadriceps tendon

Autor:innen und Institutionen

  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: John.moon@endeavorhealth.org.
  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: Camryn.A.Pletka@uth.tmc.edu.
  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: Hugh.L.Jones@uth.tmc.edu.
  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: Shuyang.Han@uth.tmc.edu.
  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: Jonathan.E.Gold@uth.tmc.edu.
  • University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, CORIT Lab, Bellaire, TX, United States. Electronic address: Sabir.K.Ismaily@uth.tmc.edu.

Förderung

  • University of Texas Health Science Center at Houston

Zitieren

APA

Moon, J., Pletka, C., Jones, H., Han, S., Gold, J., Ismaily, S., & Rodriguez, D. (2026). Biomechanical comparison of two extensor mechanism reconstruction techniques. The Knee, 61, 104440. https://doi.org/10.1016/j.knee.2026.104440

Vancouver

Moon J, Pletka C, Jones H, Han S, Gold J, Ismaily S, et al. Biomechanical comparison of two extensor mechanism reconstruction techniques. The Knee. 2026;61:104440. doi:10.1016/j.knee.2026.104440

BibTeX
@article{Moon2026,
  author = {Moon, John and Pletka, Camryn and Jones, Hugh and Han, Shuyang and Gold, Jonathan and Ismaily, Sabir and Rodriguez, David},
  title = {Biomechanical comparison of two extensor mechanism reconstruction techniques},
  journal = {The Knee},
  year = {2026},
  volume = {61},
  pages = {104440},
  doi = {10.1016/j.knee.2026.104440}
}
Kostenlos starten →