Fifteen-year survival analysis of an oxidised zirconium total knee arthroplasty
The Knee · 2023
DOI: 10.1016/j.knee.2023.10.012 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2023. Verfasst von Joseph Tr Fennelly und 5 weiteren Autor:innen. Beteiligte Einrichtung: Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom. Electronic address: jfennelly@doctors.org…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Early studies have found Oxidised Zirconium (OxZr-Nb) total knee arthroplasties to have a low incidence of failure in young, high demand patients. Theoretically this is because they are low friction and hard wearing. However, there are a paucity of studies reporting on the outcome of these implants beyond ten years. The purpose of our study was to present an in-depth 15-year survival analysis of a cemented OxZr-Nb knee arthroplasty. METHODS: Data was collected prospectively and survival analysis undertaken with multiple strict end-points. Complication rates and patient reported outcomes were measured post-operatively. RESULTS: Six hundred and seventeen knee arthroplasties were analysed. Forty-nine patients required a reoperation for various reasons. Aseptic tibial loosening was the most common cause of failure (32.7%), occurring, on average, 2.8 years after the primary procedure. There was only one oxidised zirconium femoral failure recorded. Cumulative survivorship for reoperation for any reason was 91.52% at 15-years. On average, WOMAC (Western Ontario and McMaster University) score improved by 21.2 points at one-year post-surgery, which is beyond the considered minimum clinically important difference. CONCLUSION: This study presents a 15-year survival analysis of a cemented oxidised zirconium knee arthroplasty showing good survivorship over a range of analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom. Electronic address: jfennelly@doctors.org.uk.
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom; Department of Occupational Therapy, University of Western Macedonia, 501 00, Greece. Electronic address: papale…
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom. Electronic address: jilpope89ehd@gmail.com.
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom. Electronic address: joanne.yorke@liverpoolft.nhs.uk.
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom. Electronic address: jsdavidson2@me.com.
- Lower Limb Arthroplasty Unit, Liverpool University Hospitals NHS Foundation Trust, L14 3LB, United Kingdom; Faculty of Health and Life Sciences, The University of Liverpool, L69 3BX, United Kingdom. Electronic address:…
Zitieren
APA
Fennelly, J. T., Papalexandris, S., Pope, J., Yorke, J., Davidson, J. S., & Santini, A. J. (2023). Fifteen-year survival analysis of an oxidised zirconium total knee arthroplasty. The Knee. https://doi.org/10.1016/j.knee.2023.10.012
Vancouver
Fennelly JT, Papalexandris S, Pope J, Yorke J, Davidson JS, Santini AJ. Fifteen-year survival analysis of an oxidised zirconium total knee arthroplasty. The Knee. 2023. doi:10.1016/j.knee.2023.10.012
BibTeX
@article{Fennelly2023,
author = {Fennelly, Joseph Tr and Papalexandris, Stylianos and Pope, Jill and Yorke, Joanne and Davidson, John S and Santini, Alasdair Ja},
title = {Fifteen-year survival analysis of an oxidised zirconium total knee arthroplasty},
journal = {The Knee},
year = {2023},
doi = {10.1016/j.knee.2023.10.012}
}
EUVIMED