EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Knee arthroplasty failure is associated with significant systemic multimetal exposure

Anna Flindt, Katrin Huesker, Georg Volk, Juliane Fuchs, André Hofer, Ulrich Schietsch, Georgi I Wassilew, Janosch Schoon iD, Anastasia Rakow iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-06 · 34 (6) · 2152-2160

DOI: 10.1002/ksa.70122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 27.10.2025. Verfasst von Anna Flindt und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Prosthesis Failure, Metals. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Article Processing Charge from the DFG (German Research Foundation), DFG (German Research Foundation).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study investigated whether patients scheduled for revision total knee arthroplasty (TKA) are systemically exposed to arthroplasty metals, and whether systemic metal levels in these patients differ depending on the implants' levels of constraint.

Methods

Whole blood samples were collected from patients scheduled for revision TKA (implant group, n = 51) and from arthroplasty‐naïve controls ( n = 53). Using inductively coupled plasma mass spectrometry, all TKA‐relevant metals were quantified. Differences in systemic metal levels in patients with failed unconstrained implants ( n = 31) and constrained ( n = 20) implants were analysed. Correlations between levels of the different arthroplasty metals were assessed, using the Mann–Whitney test, Kruskal–Wallis test with Dunn's multiple comparison test, Spearman r matrix, and linear regression with Spearman correlation as appropriate. A p < 0.05 was considered statistically significant.

Results

Patients scheduled for revision TKA showed significantly higher systemic Co ( p < 0.001), Cr ( p < 0.001), Mo ( p = 0.039), Ti ( p < 0.001), Nb ( p < 0.001) and Zr ( p < 0.001) levels compared with controls. Failed constrained TKA implants were associated with significantly higher levels of Co ( p = 0.002), Cr ( p = 0.005), Ti ( p = 0.047), Nb ( p = 0.023) and Zr ( p = 0.046) than detected in patients with failed unconstrained TKA implant. In patients awaiting revision of a constrained implant, whole blood levels of Co and Ti ( p < 0.001), as well as of Zr and Ti ( p < 0.001) significantly correlated, whereas no such correlations were observed in patients with failed unconstrained TKA implant.

Conclusions

Patients with failed TKA are systemically exposed to arthroplasty metals. Correlation analyses suggest a link between the release of Co and Ti as well as of Zr and Ti in patients awaiting revision of a constrained TKA implant. Additional research is required to investigate the potential biological effects of TKA‐related metals, and to establish clinically relevant systemic threshold levels. Level of Evidence Level II therapeutic study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis FailureMetalsHumansReoperationFemaleAgedMaleCobaltMiddle AgedTitaniumProsthesis DesignChromiumZirconiumMolybdenumAged, 80 and overCase-Control Studies

Stichwörter der Autor:innen

chromiumcobaltmultimetal quantificationrevision total knee arthroplastytotal knee arthroplasty (TKA)

Substanzen

CobaltTitaniumChromiumMetalsZirconiumMolybdenum

Autor:innen und Institutionen

  • Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany.
  • Immunology Department, Institute for Medical Diagnostics (IMD), Berlin, Germany.

ORCID-Profile: Janosch Schoon, Anastasia Rakow

Förderung

  • Article Processing Charge from the DFG (German Research Foundation)
  • DFG (German Research Foundation)

Zitieren

APA

Flindt, A., Huesker, K., Volk, G., Fuchs, J., Hofer, A., Schietsch, U., Wassilew, G. I., Schoon, J., & Rakow, A. (2026). Knee arthroplasty failure is associated with significant systemic multimetal exposure. Knee Surgery, Sports Traumatology, Arthroscopy, 34(6), 2152-2160. https://doi.org/10.1002/ksa.70122

Vancouver

Flindt A, Huesker K, Volk G, Fuchs J, Hofer A, Schietsch U, et al. Knee arthroplasty failure is associated with significant systemic multimetal exposure. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(6):2152-2160. doi:10.1002/ksa.70122

BibTeX
@article{Flindt2026,
  author = {Flindt, Anna and Huesker, Katrin and Volk, Georg and Fuchs, Juliane and Hofer, André and Schietsch, Ulrich and Wassilew, Georgi I and Schoon, Janosch and Rakow, Anastasia},
  title = {Knee arthroplasty failure is associated with significant systemic multimetal exposure},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {6},
  pages = {2152--2160},
  doi = {10.1002/ksa.70122}
}
Kostenlos starten →