Long-term comparison of physician-modified endografts with and without low-profile fabric designs for repair of complex abdominal and thoracoabdominal aortic aneurysms
Journal of Vascular Surgery · 2025
DOI: 10.1016/j.jvs.2025.05.204 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Vascular Surgery, 2025. Verfasst von Armin Tabiei und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis, Aortic Aneurysm, Thoracic, Endovascular Procedures, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: After commercial approval, our institution began using the Cook Zenith Alpha low-profile stent graft (LPSG) for physician-modified endograft (PMEG) repair of complex abdominal aortic aneurysms (CAAAs) and thoracoabdominal aortic aneurysms (TAAA) owing to its smaller sheath size and wider apex-to-apex stent distances, allowing for better accommodation of modifications. We aimed to compare outcomes of PMEGs using LPSGs and the standard-profile stent graft (SPSG), Zenith TX2. METHODS: We reviewed clinical data and outcomes of patients treated using PMEGs for CAAAs (short-neck infrarenal, juxtarenal, and pararenal AAAs) and TAAAs between 2007 and 2024. End points included 30-day mortality and major adverse events, patient survival, freedom from reintervention, freedom from target artery instability, and freedom from type III endoleak. RESULTS: Of 317 patients treated with PMEGs, 228 (72%) were men with a mean age of 74 ± 9 years. SPSGs were used in 174 patients (55%) and LPSGs were used in 143 patients (45%). Patients treated with LPSGs were mostly treated for TAAAs (69% vs 48%) and subsequently had more incorporated TAs per patient (3.7 ± 0.6 vs 3.1 ± 1.0) compared with the SPSG cohort (P ≤ .001). LPSGs were used more frequently with percutaneous femoral access (91% vs 36%; P ≤ .001) and less frequently with upper extremity access (41% vs 75%; P ≤ .001) and iliofemoral conduits (6% vs 21%; P ≤ .001). Technical success rates were similar between the two groups (89% LPSG vs 93% SPSG; P ≤ .001), with shorter operating time (257 ± 89 minutes vs 296 ± 107 minutes), and lower estimated blood loss (383 ± 464 mL vs 1063 ± 1221 mL) compared with the SPSG cohort (P ≤ .001). Early (30-day) mortality (5% SPSG vs 4% LPSG) and any major adverse events (30 SPSG vs 23 LPSG) were similar between two groups; however, patients in the SPSG cohort were more likely to undergo early aortic or side-branch-related reintervention (13% vs 6%; P ≤ .035). There were no significant differences in 4-year overall survival, freedom from target artery instability, freedom from reintervention, or freedom from type III endoleak rates between the two groups. CONCLUSIONS: Repair of CAAAs and TAAAs with PMEGs using devices with low-profile fabric has similar perioperative and long-term outcomes compared with standard-profile endografts, including no difference in endoleak or issues with device integrity. Confounding factors in this comparison include learning curve, improved surveillance, and treatment of more complex aneurysms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN.
- Division of Vascular and Endovascular Surgery, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas at Houston Health Science Center, Houston, TX.
- Division of Vascular Surgery and Endovascular Therapy, Keck Medical Center of University of Southern California, Los Angeles, CA.
- Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN. Electronic address: mendes.bernardo@mayo.edu.
Zitieren
APA
Tabiei, A., Chait, J., DeMartino, R. R., Oderich, G. S., Han, S. M., & Mendes, B. C. (2025). Long-term comparison of physician-modified endografts with and without low-profile fabric designs for repair of complex abdominal and thoracoabdominal aortic aneurysms. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2025.05.204
Vancouver
Tabiei A, Chait J, DeMartino RR, Oderich GS, Han SM, Mendes BC. Long-term comparison of physician-modified endografts with and without low-profile fabric designs for repair of complex abdominal and thoracoabdominal aortic aneurysms. Journal of Vascular Surgery. 2025. doi:10.1016/j.jvs.2025.05.204