Proximal sealing in the aortic arch for inner curve disease using the custom Relay scalloped and fenestrated stent graft
Journal of Vascular Surgery · 2024-11 · 80 (5) · 1317-1325.e2
DOI: 10.1016/j.jvs.2024.07.086 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Vascular Surgery, 2024-11. Verfasst von Simona Sica und 13 weiteren Autor:innen. Beteiligte Einrichtung: Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario A. Gemelli - IRCCS, Rome, Italy. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis, Endovascular Procedures, Prosthesis Design, Stents. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: This study aimed to analyze early and midterm results of custom-made proximal scallop and fenestrated stent grafts for thoracic endovascular aortic repair (TEVAR) with a proximal landing zone (PLZ) in the aortic arch. METHODS: All consecutive patients treated with the custom made proximal scalloped and fenestrated Relay stent grafts (Terumo Aortic Bolton Medical Inc.) in 10 Italian centers between January 2014 and December 2022 were included. The primary end points were technical success, incidence of intraoperative major adverse events, deployment accuracy, and rate of early neurological complications, endoleaks (ELs) and retrograde aortic dissection. RESULTS: During the study period, 49 patients received TEVAR with Relay custom-made endograft in Italy were enrolled. The median patient age was 70.1 years (interquartile range, 23-86 years) and 65.3% were male. The indication for treatment was atherosclerotic aneurysms in 59.2% of cases and penetrating aortic ulcer in 22.4%. The endograft configuration was proximal fenestration in 55.1% and scallop in 44.9%. The proximal landing zone was zone 0 in 25 cases (51%), zone 1 in 14 cases (28.6%), and zone 2 in 10 cases (20.4%). The supra-aortic debranching procedures were 38 (77.5%). Technical success was 97.9% (48/49) owing to one case (2.0%) of inaccurate deployment. Intraoperatively, one (2.0%) type Ia and one (2.0%) type III EL were detected. There were no cases of in-hospital mortality, major adverse events, or retrograde dissection. Three minor strokes (6.1%) (National Institutes of Health Stroke Scale score of ≤4) were observed. At a mean follow-up time of 36.3 ± 21.3 months the rate of types I to III ELs and reintervention was 4.1%, respectively. Four patients (8.2%) died during the follow-up period, one (2.1%) from abdominal aortic rupture and three (6.1%) from nonaortic causes. CONCLUSIONS: Our early and midterm outcomes suggest that scalloped and fenestrated TEVAR may provide an acceptable alternative treatment option for aortic arch pathologies. Large-scale studies are needed to assess the long-term durability of this technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario A. Gemelli - IRCCS, Rome, Italy.
- Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Genoa, Italy; Clinic of Vascular and Endovascular Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy.
- Vascular Surgery Unit, Manzoni Hospital, Lecco, Italy.
- School of Vascular Surgery, University of Milan, Milan, Italy.
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Pediatric and Adult CardioThoracic and Vascular, Oncohematologic and Emergency Radiology Unit, Bologna, Italy.
- Unit of Vascular and Endovascular Surgery, Grande Ospedale Metropolitano "Bianchi-Melacrino-Morelli", Reggio Calabria, Italy.
Zitieren
APA
Sica, S., Pratesi, G., Rossi, G., Ferraresi, M., Lovato, L., Volpe, P., Fadda, G. F., Ferri, M., Rizza, A., D'Oria, M., Micheli, R., Tshomba, Y., Tinelli, G., & OSCAR (prOximal Sealing aortiC ARch) Collaborative Study Group (2024). Proximal sealing in the aortic arch for inner curve disease using the custom Relay scalloped and fenestrated stent graft. Journal of Vascular Surgery, 80(5), 1317-1325.e2. https://doi.org/10.1016/j.jvs.2024.07.086
Vancouver
Sica S, Pratesi G, Rossi G, Ferraresi M, Lovato L, Volpe P, et al. Proximal sealing in the aortic arch for inner curve disease using the custom Relay scalloped and fenestrated stent graft. Journal of Vascular Surgery. 2024;80(5):1317-1325.e2. doi:10.1016/j.jvs.2024.07.086
BibTeX
@article{Sica2024,
author = {Sica, Simona and Pratesi, Giovanni and Rossi, Giovanni and Ferraresi, Marco and Lovato, Luigi and Volpe, Pietro and Fadda, Gian Franco and Ferri, Michelangelo and Rizza, Antonio and D'Oria, Mario and Micheli, Raimondo and Tshomba, Yamume and Tinelli, Giovanni and OSCAR (prOximal Sealing aortiC ARch) Collaborative Study Group, OSCAR (prOximal Sealing aortiC ARch) Collaborative Study Group},
title = {Proximal sealing in the aortic arch for inner curve disease using the custom Relay scalloped and fenestrated stent graft},
journal = {Journal of Vascular Surgery},
year = {2024},
volume = {80},
number = {5},
pages = {1317--1325.e2},
doi = {10.1016/j.jvs.2024.07.086}
}