Fachartikel in der Zeitschrift Journal of Vascular Surgery, 2024-06. Verfasst von Thomas F X O'Donnell und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac, Thoracic, and Vascular Surgery, New York-Presbyterian/Columbia University Irving Medical Center/Columbia University Vagelos Coll…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis, Endovascular Procedures, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Custom-branched/fenestrated grafts are widely available in other countries, but in the United States, they are limited to a handful of centers, with the exception of a 3-vessel juxtarenal device (ZFEN). Consequently, many surgeons have turned to alternative strategies such as physician-modified endografts (PMEGs). We therefore sought to determine how widespread the use of these grafts is. METHODS: We studied all complex endovascular repairs of complex and thoracoabdominal aortic aneurysms in the Vascular Quality Initiative from 2014 to 2022 to examine temporal trends. RESULTS: A total of 5826 repairs were performed during the study period: 1895 ZFEN, 3241 PMEG, 595 parallel grafting, and 95 where parallel grafting was used in addition to ZFEN, with a mean of 2.7 ± 0.98 vessels incorporated. Over time, the number of PMEGs steadily increased, both overall and for juxtarenal aneurysms, whereas the number of ZFENs essentially leveled off by 2017 and has remained steady ever since. In the most recent complete year (2021), PMEGs outnumbered ZFENs by over 2:1 overall (567 to 256) and nearly twofold for juxtarenal repairs. In three-vessel cases involving juxtarenal aneurysms, PMEGs were used as frequently as ZFENs (43% vs 43%), whereas the proportion of juxtarenal aneurysms repaired using a four-vessel graft configuration increased from 20% in 2014 to 29% in 2021 (P < .001). The differences in PMEG use were more pronounced as surgeon volume increased. Surgeons in the lowest quartile of volume performed
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiac, Thoracic, and Vascular Surgery, New York-Presbyterian/Columbia University Irving Medical Center/Columbia University Vagelos College of Physicians & Surgeons, New York, NY. Electronic address: tfo210…
- Division of Vascular and Endovascular Surgery, University of Washington, Seattle, WA.
- Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.
- Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN.
- Division of Cardiac, Thoracic, and Vascular Surgery, New York-Presbyterian/Columbia University Irving Medical Center/Columbia University Vagelos College of Physicians & Surgeons, New York, NY.
Zitieren
APA
O'Donnell, T. F. X., Dansey, K. D., Schermerhorn, M. L., Zettervall, S. L., DeMartino, R. R., Takayama, H., & Patel, V. I. (2024). National trends in utilization of surgeon-modified grafts for complex and thoracoabdominal aortic aneurysms. Journal of Vascular Surgery, 79(6), 1276-1284. https://doi.org/10.1016/j.jvs.2024.01.216
Vancouver
O'Donnell TFX, Dansey KD, Schermerhorn ML, Zettervall SL, DeMartino RR, Takayama H, et al. National trends in utilization of surgeon-modified grafts for complex and thoracoabdominal aortic aneurysms. Journal of Vascular Surgery. 2024;79(6):1276-1284. doi:10.1016/j.jvs.2024.01.216
BibTeX
@article{ODonnell2024,
author = {O'Donnell, Thomas F X and Dansey, Kirsten D and Schermerhorn, Marc L and Zettervall, Sara L and DeMartino, Randall R and Takayama, Hiroo and Patel, Virendra I},
title = {National trends in utilization of surgeon-modified grafts for complex and thoracoabdominal aortic aneurysms},
journal = {Journal of Vascular Surgery},
year = {2024},
volume = {79},
number = {6},
pages = {1276--1284},
doi = {10.1016/j.jvs.2024.01.216}
}
EUVIMED