EUVIMEDEUVIMED entdecken
Multizentrische StudieKlinische StudieOpen Access · CC BY-NC-ND 4.0

Early outcomes from the pivotal trial of a four-branch off-the shelf solution to treat complex abdominal and type IV thoracoabdominal aortic aneurysms

Mark A Farber, Jon S Matsumura, Sukgu Han, Michel S Makaroun, Bjoern D Suckow, Carlos H Timaran, Bernardo C Mendes, Gustavo S Oderich

Journal of Vascular Surgery · 2024-11 · 80 (5) · 1326-1335.e4

DOI: 10.1016/j.jvs.2024.05.020 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Vascular Surgery, 2024-11. Verfasst von Mark A Farber und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular and Surgery, University of North Carolina, Chapel Hill, NC. Electronic address: mark_farber@med.unc.edu. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Endovascular Procedures, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: W L Gore and Associates.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study reports the 30-day outcomes of the primary arm of the GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE) pivotal trial for complex abdominal aortic aneurysm repair. METHODS: This multicenter, nonrandomized, prospective study of the TAMBE device included patients enrolled in the primary study arm of extent IV thoracoabdominal aortic aneurysms and pararenal aneurysms. Technical success and major adverse events were analyzed per the Society for Vascular Surgery guidelines. RESULTS: The 102 patients of the primary arm who underwent endovascular repair using the TAMBE device were a mean age of 73 ± 6.4 years (range, 58-82 years) and 84 (84.2%) were male. The mean body mass index was 28.3 ± 5.0 kg/m2. Fifty-nine patients (57.8%) were treated for extent IV and 43 (42.2%) pararenal aneurysms; the mean maximum diameter of the aneurysms was 59.4 ± 7.8 mm. A prophylactic cerebral spinal fluid drain was used in 10 patients (9.8%). Technical success was achieved in 99% of patients, with the single failure owing to unsuccessful cannulation of the left renal artery. Mean procedure time was 315 ± 103 minutes (range, 163-944 minutes), estimated blood loss was 300 ± 296 mL (range, 10-2000 mL), and contrast administration was 153.6 ± 73.5 mL (range, 16-420 mL). The intensive care unit length of stay was 58.7 ± 52.7 hours (range, 1-288 mL). In 28 patients (27.5%), a total of 32 additional endovascular components were deployed to manage procedural complications including aortic and target vessel dissections and injuries not related to access. Bridging stent grafts were deployed to incorporate 407 target vessels (mean 1.6/per vessel; range, 1-4). Postoperative transfusion was required in 14 patients (13.7%). Major adverse events occurred in seven patients (6.9%) through 30 days. Events included respiratory failure (n = 2), disabling stroke (n = 1), new-onset renal failure requiring dialysis (n = 2), and paraplegia (n = 2). At 30 days, there was one patient with intraoperative rupture; no severe bowel ischemia or lesion-related/all-cause mortality were reported. The Core lab-reported patency was 100% in the aortic component, superior mesenteric artery, and celiac artery, and 95.9% in the left renal and 99.0% in the right renal branch components through 30 days of follow-up. Reinterventions through 30 days were performed in 9 of 96 patients (9.4%) and were all minor. CONCLUSIONS: Early TAMBE device outcomes demonstrate a high technical success rate, no 30-day lesion-related mortality, and a low rate of safety events within 30 days of the index procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, ThoracicEndovascular ProceduresBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationProsthesis DesignAortic Aneurysm, AbdominalPostoperative ComplicationsHumansMaleAgedFemaleMiddle AgedAged, 80 and overProspective StudiesTreatment OutcomeTime FactorsRisk FactorsStentsUnited StatesLength of StayAortic Aneurysm, Thoracoabdominal

Stichwörter der Autor:innen

AneurysmEndovascular graftingEndovascular interventionsEndovascular repairParasuprarenalThoracic/thoracoabdominal

Autor:innen und Institutionen

  • Division of Vascular and Surgery, University of North Carolina, Chapel Hill, NC. Electronic address: mark_farber@med.unc.edu.
  • Division of Vascular Surgery, University of Colorado School of Medicine, Aurora, CO.
  • Division of Vascular Surgery, Keck Medical Center of University of Southern California, Los Angeles, CA.
  • University of Pittsburgh Medical Center, Pittsburgh, PA.
  • Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • University of Texas Southwestern Medical Center, Dallas, TX.

Förderung

  • W L Gore and Associates

Zitieren

APA

Farber, M. A., Matsumura, J. S., Han, S., Makaroun, M. S., Suckow, B. D., Timaran, C. H., Mendes, B. C., & Oderich, G. S. (2024). Early outcomes from the pivotal trial of a four-branch off-the shelf solution to treat complex abdominal and type IV thoracoabdominal aortic aneurysms. Journal of Vascular Surgery, 80(5), 1326-1335.e4. https://doi.org/10.1016/j.jvs.2024.05.020

Vancouver

Farber MA, Matsumura JS, Han S, Makaroun MS, Suckow BD, Timaran CH, et al. Early outcomes from the pivotal trial of a four-branch off-the shelf solution to treat complex abdominal and type IV thoracoabdominal aortic aneurysms. Journal of Vascular Surgery. 2024;80(5):1326-1335.e4. doi:10.1016/j.jvs.2024.05.020

BibTeX
@article{Farber2024,
  author = {Farber, Mark A and Matsumura, Jon S and Han, Sukgu and Makaroun, Michel S and Suckow, Bjoern D and Timaran, Carlos H and Mendes, Bernardo C and Oderich, Gustavo S},
  title = {Early outcomes from the pivotal trial of a four-branch off-the shelf solution to treat complex abdominal and type IV thoracoabdominal aortic aneurysms},
  journal = {Journal of Vascular Surgery},
  year = {2024},
  volume = {80},
  number = {5},
  pages = {1326--1335.e4},
  doi = {10.1016/j.jvs.2024.05.020}
}
Kostenlos starten →