EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model

Carlos B Ortiz, Kade Derrick, Annie Dang, Marina Borrego, Seiji Yamaguchi, Daniel Grosser, Leon Bunegin, John Walker, Jorge Lopera

Journal of Vascular and Interventional Radiology · 2024-10 · 35 (10) · 1551-1557.e1

DOI: 10.1016/j.jvir.2024.06.012 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Vascular and Interventional Radiology, 2024-10. Verfasst von Carlos B Ortiz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; Long School of Medicine, The University of T…. Hauptthemen laut MEDLINE: Kidney, Embolization, Therapeutic, Microwaves, Perfusion. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To utilize a novel ex vivo perfused human renal model and quantify microwave ablation (MWA) size differences in renal tissue when combining MWA with transarterial embolization (TAE). MATERIALS AND METHODS: Human kidneys (n = 5) declined for transplantation were obtained and connected to a fluoroscopy-compatible ex vivo perfusion system. Two ablations-1 standard MWA and 1 TAE-MWA-were performed in each kidney for 2 minutes at 100 W using a MWA system (Solero Angiodynamics). MWA alone was performed in the upper pole. In the lower pole, MWA was performed after TAE with 40-90 μm radiopaque microspheres to achieve angiographic stasis. Ablation zones of coagulative necrosis were sectioned along the long axis and segmented for maximal short-axis diameter (SAD) and long-axis diameter (LAD) measurements. RESULTS: A total of 10 ablations (5 MWAs and 5 TAE-MWAs) were performed in 5 human kidneys. TAE-MWA resulted in significantly increased SAD, LAD, volume, and sphericity compared with standard MWA ± SD, with mean measurements as follows (5 standard MWAs ± SD vs 5 TAE-MWAs ± SD, 2-tailed t-test): (a) SAD, 1.8 cm (SD ± 0.1) versus 2.5 cm (SD ± 0.1) (P < .001); (b) LAD, 2.9 cm (SD ± 0.3) versus 3.2 cm (SD ± 0.1) (P = .039); (c) volume, 5.0 mL (SD ± 0.5) versus 11.0 mL (SD ± 0.7) (P < .001); and (d) sphericity, 0.4 (SD ± 0.2) versus 0.6 (SD ± 0.1) (P = .049). Histology demonstrated no differences in TAE-MWA other than concentrated microspheres. CONCLUSIONS: This ex vivo human kidney perfusion model confirmed that combined MWA-TAE significantly increased ablation size and spherical shape compared with MWA alone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KidneyEmbolization, TherapeuticMicrowavesPerfusionHumansAblation TechniquesIn Vitro TechniquesNecrosis

Autor:innen und Institutionen

  • Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas. Electroni…
  • Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas.
  • Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas.
  • Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; University Transplant Center, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas.
  • Department of Pathology, Case Western Reserve University, Cleveland, Ohio.
  • Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; Vascular Perfusion Solutions, San Antonio, Texas.

Förderung

  • NIGMS NIH HHS

Zitieren

APA

Ortiz, C. B., Derrick, K., Dang, A., Borrego, M., Yamaguchi, S., Grosser, D., Bunegin, L., Walker, J., & Lopera, J. (2024). Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model. Journal of Vascular and Interventional Radiology, 35(10), 1551-1557.e1. https://doi.org/10.1016/j.jvir.2024.06.012

Vancouver

Ortiz CB, Derrick K, Dang A, Borrego M, Yamaguchi S, Grosser D, et al. Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model. Journal of Vascular and Interventional Radiology. 2024;35(10):1551-1557.e1. doi:10.1016/j.jvir.2024.06.012

BibTeX
@article{Ortiz2024,
  author = {Ortiz, Carlos B and Derrick, Kade and Dang, Annie and Borrego, Marina and Yamaguchi, Seiji and Grosser, Daniel and Bunegin, Leon and Walker, John and Lopera, Jorge},
  title = {Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model},
  journal = {Journal of Vascular and Interventional Radiology},
  year = {2024},
  volume = {35},
  number = {10},
  pages = {1551--1557.e1},
  doi = {10.1016/j.jvir.2024.06.012}
}
Kostenlos starten →