Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model
Journal of Vascular and Interventional Radiology · 2024
DOI: 10.1016/j.jvir.2024.05.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Vascular and Interventional Radiology, 2024. Verfasst von Hiro Sparks und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California. Electronic address: HDSparks@me…. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Microwaves, Liver, Hepatic Artery. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: To characterize the relationship between ablation zone volume (AZV) and microwave ablation (MWA) energy in an in vivo porcine liver model following arterial embolization. MATERIALS AND METHODS: With Institutional Animal Care and Use Committee (IACUC) approval, 11 female swine underwent either right (n = 5) or left (n = 6) hepatic artery embolization under fluoroscopic guidance. Subsequently, ultrasound (US)-guided MWA was performed in each liver segment (left lateral, left medial, right medial, and right lateral) at either 30 W (n = 4 lobes), 60 W (n = 4), 65 W (n = 20), 90 W (n = 8), 120 W (n = 4), or 140 W (n = 4) continuously for 5 minutes. Postprocedural volumetric segmentation was performed on standardized multiphase T1 magnetic resonance (MR) imaging sequences. RESULTS: Mean AZVs in embolized lobes (15.8 mL ± SD 10.6) were significantly larger than those in nonembolized lobes (11.2 mL ± SD 6.5, P < .01). MWA energy demonstrated significant positive linear correlation with both embolized (R2 = 0.66, P < .01) and nonembolized (R2 = 0.64, P < .01) lobes. The slope of the linear models corresponded to a 0.95 mL/kJ (SD ± 0.16) and 0.54 mL/kJ (SD ± 0.09) increase in ablation volume per applied kilojoule of energy (E) in embolized and nonembolized lobes, respectively. In the multivariate model, embolization status significantly modified the relationship between E and AZV as described by the following interaction term: 0.42∗E∗(embolization status) (P = .031). CONCLUSIONS: Linear models demonstrated a near 1.8-fold increase in ratio of AZV per unit E, R(AZV:E), when applied to embolized lobes relative to nonembolized lobes. Absolute AZV differences between embolized and nonembolized lobes were greater at higher-power MWA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California. Electronic address: HDSparks@mednet.ucla.edu.
- Department for Radiology and Nuclear Medicine, Mannheim University Medical Centre, Mannheim, Germany.
- Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California.
Zitieren
APA
Sparks, H., Rink, J. S., Ramakrishnan, A., Sung, K., Ni, J., Lu, D. S. K., Raman, S. S., Lee, E. W., & Chiang, J. (2024). Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/j.jvir.2024.05.005
Vancouver
Sparks H, Rink JS, Ramakrishnan A, Sung K, Ni J, Lu DSK, et al. Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model. Journal of Vascular and Interventional Radiology. 2024. doi:10.1016/j.jvir.2024.05.005
BibTeX
@article{Sparks2024,
author = {Sparks, Hiro and Rink, Johann S and Ramakrishnan, Abinaya and Sung, Kyunghun and Ni, Jason and Lu, David S K and Raman, Steven S and Lee, Edward W and Chiang, Jason},
title = {Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model},
journal = {Journal of Vascular and Interventional Radiology},
year = {2024},
doi = {10.1016/j.jvir.2024.05.005}
}