EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model

Hiro Sparks, Johann S Rink, Abinaya Ramakrishnan, Kyunghun Sung, Jason Ni, David S K Lu, Steven S Raman, Edward W Lee, Jason Chiang

Journal of Vascular and Interventional Radiology · 2024

DOI: 10.1016/j.jvir.2024.05.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular and Interventional Radiology, 2024. Verfasst von Hiro Sparks und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California. Electronic address: HDSparks@me…. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Microwaves, Liver, Hepatic Artery. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To characterize the relationship between ablation zone volume (AZV) and microwave ablation (MWA) energy in an in vivo porcine liver model following arterial embolization. MATERIALS AND METHODS: With Institutional Animal Care and Use Committee (IACUC) approval, 11 female swine underwent either right (n = 5) or left (n = 6) hepatic artery embolization under fluoroscopic guidance. Subsequently, ultrasound (US)-guided MWA was performed in each liver segment (left lateral, left medial, right medial, and right lateral) at either 30 W (n = 4 lobes), 60 W (n = 4), 65 W (n = 20), 90 W (n = 8), 120 W (n = 4), or 140 W (n = 4) continuously for 5 minutes. Postprocedural volumetric segmentation was performed on standardized multiphase T1 magnetic resonance (MR) imaging sequences. RESULTS: Mean AZVs in embolized lobes (15.8 mL ± SD 10.6) were significantly larger than those in nonembolized lobes (11.2 mL ± SD 6.5, P < .01). MWA energy demonstrated significant positive linear correlation with both embolized (R2 = 0.66, P < .01) and nonembolized (R2 = 0.64, P < .01) lobes. The slope of the linear models corresponded to a 0.95 mL/kJ (SD ± 0.16) and 0.54 mL/kJ (SD ± 0.09) increase in ablation volume per applied kilojoule of energy (E) in embolized and nonembolized lobes, respectively. In the multivariate model, embolization status significantly modified the relationship between E and AZV as described by the following interaction term: 0.42∗E∗(embolization status) (P = .031). CONCLUSIONS: Linear models demonstrated a near 1.8-fold increase in ratio of AZV per unit E, R(AZV:E), when applied to embolized lobes relative to nonembolized lobes. Absolute AZV differences between embolized and nonembolized lobes were greater at higher-power MWA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Embolization, TherapeuticMicrowavesLiverHepatic ArteryModels, AnimalAnimalsFemaleSwineAblation TechniquesSus scrofaMagnetic Resonance ImagingUltrasonography, Interventional

Autor:innen und Institutionen

  • Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California. Electronic address: HDSparks@mednet.ucla.edu.
  • Department for Radiology and Nuclear Medicine, Mannheim University Medical Centre, Mannheim, Germany.
  • Department of Radiology, Ronald Reagan University of California, Los Angeles Medical Center, Los Angeles, California.

Zitieren

APA

Sparks, H., Rink, J. S., Ramakrishnan, A., Sung, K., Ni, J., Lu, D. S. K., Raman, S. S., Lee, E. W., & Chiang, J. (2024). Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/j.jvir.2024.05.005

Vancouver

Sparks H, Rink JS, Ramakrishnan A, Sung K, Ni J, Lu DSK, et al. Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model. Journal of Vascular and Interventional Radiology. 2024. doi:10.1016/j.jvir.2024.05.005

BibTeX
@article{Sparks2024,
  author = {Sparks, Hiro and Rink, Johann S and Ramakrishnan, Abinaya and Sung, Kyunghun and Ni, Jason and Lu, David S K and Raman, Steven S and Lee, Edward W and Chiang, Jason},
  title = {Characterization of Microwave Generator Energy and Ablation Volumes following Transarterial Embolization in an In Vivo Porcine Liver Model},
  journal = {Journal of Vascular and Interventional Radiology},
  year = {2024},
  doi = {10.1016/j.jvir.2024.05.005}
}