EUVIMEDEUVIMED entdecken
Multizentrische Studie

Pre-emptive Aortic Side Branch Embolization during Endovascular Aneurysm Repair Using the Excluder Stent-Graft System: A Prospective Multicenter study

Koji Sasaki, Masato Yamaguchi, Tomoyuki Gentsu, Ryota Kawasaki, Naokazu Miyamoto, Kensuke Uotani, Noriaki Sakamoto, Tetsuya Fukuda, Hiroki Horinouchi, Takanori Taniguchi, Takeki Mori, Yojiro Koda und 11 weitere

Journal of Vascular and Interventional Radiology · 2024

DOI: 10.1016/j.jvir.2024.01.032 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Vascular and Interventional Radiology, 2024. Verfasst von Koji Sasaki und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, Hyogo, Japan. Hauptthemen laut MEDLINE: Endovascular Procedures, Aortic Aneurysm, Abdominal, Embolization, Therapeutic, Endoleak. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the effectiveness and safety of pre-emptive transcatheter arterial embolization (P-TAE) for aortic side branches (ASBs) to prevent Type 2 endoleaks (EL2) before endovascular aneurysm repair (EVAR) using the Excluder stent-graft system (Excluder). MATERIALS AND METHODS: In this prospective, multicenter study, 80 patients (mean age, 79.1 years [SD ± 6.7]; 85.0% were men; mean aneurysmal sac diameter, 48.4 mm [SD ± 7.4]) meeting the eligibility criteria were prospectively enrolled from 9 hospitals. Before EVAR, P-TAE was performed to embolize the patent ASBs originating from the abdominal aortic aneurysm. Contrast-enhanced computed tomography (CT) was performed at 1 month and 6 months after EVAR. The primary endpoint was EL2 incidence at 6 months, and the secondary endpoints were aneurysmal sac diameter changes at 6 and 12 months, P-TAE outcomes, adverse events related to P-TAE, reintervention, and aneurysm-related mortality. RESULTS: All patients successfully underwent P-TAE without serious. Coil embolization was successful in 81.6% of ASBs. EL2 incidence at 6 months was identified in 18 of 70 (25.7%) patients. Aneurysmal sac diameter shrinkage (≥5 mm) was observed in 30.0% of patients at 6 months and in 40.9% at 12 months. Only 1 patient required reintervention for EL2 within 1 year of EVAR; aneurysm-related deaths were not observed. CONCLUSIONS: P-TAE for ASBs before EVAR using Excluder is a safe and effective strategy. It aids in achieving early aneurysmal sac shrinkage and reduces EL2 reintervention at 1 year after EVAR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular ProceduresAortic Aneurysm, AbdominalEmbolization, TherapeuticEndoleakBlood Vessel ProsthesisStentsBlood Vessel Prosthesis ImplantationProsthesis DesignComputed Tomography AngiographyHumansFemaleMaleAgedProspective StudiesTreatment OutcomeAged, 80 and overTime FactorsAortographyRisk FactorsJapanEndovascular Aneurysm Repair

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, Hyogo, Japan.
  • Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, Hyogo, Japan. Electronic address: masato03310402@yahoo.co.jp.
  • Department of Diagnostic and Interventional Radiology, Hyogo Prefectural Harima-Himeji General Medical Center, Himeji, Hyogo, Japan.
  • Department of Diagnostic Radiology, Kita-Harima Medical Center, Ono, Hyogo, Japan.
  • Department of Radiology, Hyogo Prefectural Awaji Medical Center, Sumoto, Hyogo, Japan.
  • Department of Diagnostic and Interventional Radiology, Kakogawa Central City Hospital, Kakogawa, Hyogo, Japan.

Zitieren

APA

Sasaki, K., Yamaguchi, M., Gentsu, T., Kawasaki, R., Miyamoto, N., Uotani, K., Sakamoto, N., Fukuda, T., Horinouchi, H., Taniguchi, T., Mori, T., Koda, Y., Yamanaka, K., Takahashi, H., Okada, K., Watanabe, T., Hayashi, T., Nomura, Y., Matsushiro, K., …, & Murakami, T. (2024). Pre-emptive Aortic Side Branch Embolization during Endovascular Aneurysm Repair Using the Excluder Stent-Graft System: A Prospective Multicenter study. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/j.jvir.2024.01.032

Vancouver

Sasaki K, Yamaguchi M, Gentsu T, Kawasaki R, Miyamoto N, Uotani K, et al. Pre-emptive Aortic Side Branch Embolization during Endovascular Aneurysm Repair Using the Excluder Stent-Graft System: A Prospective Multicenter study. Journal of Vascular and Interventional Radiology. 2024. doi:10.1016/j.jvir.2024.01.032

BibTeX
@article{Sasaki2024,
  author = {Sasaki, Koji and Yamaguchi, Masato and Gentsu, Tomoyuki and Kawasaki, Ryota and Miyamoto, Naokazu and Uotani, Kensuke and Sakamoto, Noriaki and Fukuda, Tetsuya and Horinouchi, Hiroki and Taniguchi, Takanori and Mori, Takeki and Koda, Yojiro and Yamanaka, Katsuhiro and Takahashi, Hiroaki and Okada, Kenji and Watanabe, Toshitaka and Hayashi, Taro and Nomura, Yoshikatsu and Matsushiro, Keigo and Ueshima, Eisuke and Okada, Takuya and Sugimoto, Koji and Murakami, Takamichi},
  title = {Pre-emptive Aortic Side Branch Embolization during Endovascular Aneurysm Repair Using the Excluder Stent-Graft System: A Prospective Multicenter study},
  journal = {Journal of Vascular and Interventional Radiology},
  year = {2024},
  doi = {10.1016/j.jvir.2024.01.032}
}
Kostenlos starten →