Efficacy of the Preloading Coil-In-Plug Method for Internal Iliac Artery Embolization
Annals of Vascular Surgery · 2026-01 · 122 · 627-634
DOI: 10.1016/j.avsg.2025.09.008 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Vascular Surgery, 2026-01. Verfasst von Nagi Hayashi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Saga University, Saga, Japan. Electronic address: qywfr603@yahoo.co.jp. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Endovascular Procedures, Iliac Artery, Iliac Aneurysm. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: During endovascular aneurysm repair (EVAR), embolization of the internal iliac artery (IIA) is sometimes necessary. The preloading coil-in-plug (P-CIP) technique allows high-density embolization within a confined area. This retrospective study at our institution evaluated the efficacy of the P-CIP technique and compared it with conventional coil embolization (CE). METHODS: Between January 2015 and December 2023, 201 patients underwent EVAR. Seventy-three patients underwent IIA trunk embolization. Patients who underwent embolization using only an Amplatzer vascular plug (AVP) or P-CIP using an AVP2 were excluded. Fifty-six patients (mean age, 76.7 years; 11 female patients) were categorized into the P-CIP (25 patients) and CE (31 patients) groups. RESULTS: The embolization site vessel diameter (8.08 ± 1.9 mm vs 8.01 ± 2.2 mm; P = 0.85), procedure time (36.4 ± 3.1 minutes vs 34.0 ± 3.1 minutes; P = 0.45) and incidence of type 2 endoleaks (0 [0%] vs. 1 [3.2%]; P = 0.27) of both groups were not significantly different. Compared to the CE group, the P-CIP group required fewer coils (3.36 ± 0.26 vs 4.30 ± 0.24; P = 0.037) and had a significantly higher complete occlusion rate (19 [76.0%] vs 10 [32.3%]; P < 0.002). Compared to the CE group, the P-CIP group had a significantly smaller embolization range (20.1 ± 5.46 mm vs. 31.7 ± 7.2 mm; P < 0.001); however, the buttock claudication incidence was not significantly different (13 [52.0%] vs 13 [41.9%]; P = 0.45). All patients experienced full recovery of buttock claudication within 1 year postoperatively. CONCLUSION: The P-CIP technique enabled effective and reliable embolization of the IIA trunk and demonstrated advantages over conventional CE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Thoracic and Cardiovascular Surgery, Saga University, Saga, Japan. Electronic address: qywfr603@yahoo.co.jp.
- Department of Thoracic and Cardiovascular Surgery, Saga University, Saga, Japan.
Zitieren
APA
Hayashi, N., Yunoki, J., Tanaka, A., Shigetomi, K., Baba, K., Shichijo, M., Jinnouchi, K., Morokuma, H., Itoh, M., & Kamohara, K. (2026). Efficacy of the Preloading Coil-In-Plug Method for Internal Iliac Artery Embolization. Annals of Vascular Surgery, 122, 627-634. https://doi.org/10.1016/j.avsg.2025.09.008
Vancouver
Hayashi N, Yunoki J, Tanaka A, Shigetomi K, Baba K, Shichijo M, et al. Efficacy of the Preloading Coil-In-Plug Method for Internal Iliac Artery Embolization. Annals of Vascular Surgery. 2026;122:627-634. doi:10.1016/j.avsg.2025.09.008
BibTeX
@article{Hayashi2026,
author = {Hayashi, Nagi and Yunoki, Junji and Tanaka, Atsuhisa and Shigetomi, Keijiro and Baba, Kouhei and Shichijo, Masahide and Jinnouchi, Kouki and Morokuma, Hiroyuki and Itoh, Manabu and Kamohara, Keiji},
title = {Efficacy of the Preloading Coil-In-Plug Method for Internal Iliac Artery Embolization},
journal = {Annals of Vascular Surgery},
year = {2026},
volume = {122},
pages = {627--634},
doi = {10.1016/j.avsg.2025.09.008}
}
EUVIMED