EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs

N Schreiber, R Willis, T Glaus, M Baron Toaldo

Journal of Veterinary Cardiology · 2023

DOI: 10.1016/j.jvc.2023.04.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2023. Verfasst von N Schreiber und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Clinic for Small Animal Internal Medicine, Vetsuisse Faculty University of Zürich, Switzerland. Hauptthemen laut MEDLINE: Atrial Fibrillation, Tachycardia, Ventricular, Ventricular Premature Complexes, Dog Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION/OBJECTIVES: The aim of this study was to compare a novel small event recorder device, the Carnation Ambulatory Monitor (CAM), with a standard Holter. ANIMALS: Nineteen adult dogs. MATERIAL AND METHODS: Comparative and explorative study. The two devices were simultaneously applied for approximately 24 h. RESULTS: Analysis time (P=0.013) and percentage of artefacts (P 300ventricular premature complexes), and underestimation of complex ventricular arrhythmias, the CAM appears not suitable for quantitative arrhythmia analysis in dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationTachycardia, VentricularVentricular Premature ComplexesDog DiseasesDogsAnimalsElectrocardiography, AmbulatoryElectrocardiography

Stichwörter der Autor:innen

ArrhythmiaCanineEvent recorderLown grade

Autor:innen und Institutionen

  • Division of Cardiology, Clinic for Small Animal Internal Medicine, Vetsuisse Faculty University of Zürich, Switzerland.
  • Sarah Smith Cardiology, Ivy Court, Willington Road, Etwall, Derby, DE65 6JG, UK.
  • Division of Cardiology, Clinic for Small Animal Internal Medicine, Vetsuisse Faculty University of Zürich, Switzerland. Electronic address: marco.barontoaldo@uzh.ch.

Zitieren

APA

Schreiber, N., Willis, R., Glaus, T., & Baron Toaldo, M. (2023). Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2023.04.004

Vancouver

Schreiber N, Willis R, Glaus T, Baron Toaldo M. Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs. Journal of Veterinary Cardiology. 2023. doi:10.1016/j.jvc.2023.04.004

BibTeX
@article{Schreiber2023,
  author = {Schreiber, N and Willis, R and Glaus, T and Baron Toaldo, M},
  title = {Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs},
  journal = {Journal of Veterinary Cardiology},
  year = {2023},
  doi = {10.1016/j.jvc.2023.04.004}
}
Kostenlos starten →