Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation
Journal of Veterinary Cardiology · 2026
DOI: 10.1016/j.jvc.2025.10.002 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of Veterinary Cardiology, 2026. Verfasst von M I Oliveira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hospital for Small Animals, Royal (Dick) School of Veterinary Studies & The Roslin Institute, University of Edinburgh, Roslin, EH25 9RG, UK. Electron…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Dog Diseases, Electrocardiography, Ambulatory. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
INTRODUCTION/OBJECTIVES: Fast ventricular response rates (VRRs) have negative prognostic value in atrial fibrillation (AF). Therapeutic recommendations for canine AF rely on measurements of VRR from ambulatory electrocardiograms (aECGs). ANIMALS, MATERIALS AND METHODS: Data from aECG of dogs with AF were prospectively acquired alongside VRR measurements obtained at home using a smartphone-based ECG device between 7:00 and 23:00. From these data, three protocols were outlined: (A) three eight-hourly spot-checks, (B) three six-hourly spot-checks, and (C) five predetermined spot-checks. The performance of the protocols was compared with aECG using mesor, mean and median VRR. The presence of circadian variation was explored using cosinor analysis. RESULTS: Eighteen aECGs were analysed, and 14 were used to test the spot-check protocols. The protocols showed moderate to strong correlation with aECG, with protocol B performing best (mean, r = 0.84, P= 140 bpm. Circadian variation in VRR was identified in 17 of 18 dogs (94%). LIMITATIONS: This study is limited by the small population, highly prevalent inadequate VRR, non-standardised treatment, measurement artefacts and precise temporal alignment with aECG. CONCLUSIONS: Spot-check protocols offer a practical, affordable alternative to aECG for VRR assessment in dogs with AF. A mean VRR >140 bpm in the protocol predicts inadequate rate control on aECG.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hospital for Small Animals, Royal (Dick) School of Veterinary Studies & The Roslin Institute, University of Edinburgh, Roslin, EH25 9RG, UK. Electronic address: Molivei2@ed.ac.uk.
- Hospital for Small Animals, Royal (Dick) School of Veterinary Studies & The Roslin Institute, University of Edinburgh, Roslin, EH25 9RG, UK.
Zitieren
APA
Oliveira, M. I., Culshaw, G., Dickson, S. A., Blake, R., & Martinez Pereira, Y. (2026). Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2025.10.002
Vancouver
Oliveira MI, Culshaw G, Dickson SA, Blake R, Martinez Pereira Y. Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation. Journal of Veterinary Cardiology. 2026. doi:10.1016/j.jvc.2025.10.002
BibTeX
@article{Oliveira2026,
author = {Oliveira, M I and Culshaw, G and Dickson, S-A and Blake, R and Martinez Pereira, Y},
title = {Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation},
journal = {Journal of Veterinary Cardiology},
year = {2026},
doi = {10.1016/j.jvc.2025.10.002}
}
EUVIMED