EUVIMEDEUVIMED entdecken
Crossref

Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system

K V Pierce, B A Scansen, S Rao

Journal of Veterinary Cardiology · 2023

DOI: 10.1016/j.jvc.2023.03.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2023. Verfasst von K V Pierce und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Colorado State University, Fort Collins, CO 80523, USA. Electronic address: kvpierce@ncsu.edu. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent, Cardiac Catheterization, Dog Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units. ANIMALS: One hundred and fifty-four client-owned dogs. MATERIALS AND METHODS: Patient dose during procedures using a portable C-arm were retrospectively analyzed and compared to those performed in a contemporary interventional suite. Fluoroscopy equipment, procedure type, operator, patient weight, fluoroscopy time, dose area product, and air kerma were recorded and statistically modeled using univariable and multivariable linear regression to evaluate the effect of each factor. RESULTS: Patient dose population (154 dogs), comprised 61 patent ductus arteriosus occlusions, 60 balloon pulmonary valvuloplasties, and 33 pacemaker implantations. Patient dose was significantly lower in the group utilizing a newer generation fluoroscopy unit vs. the group utilizing an older portable C-arm, positively correlated with patient weight, and highest during balloon pulmonary valvuloplasties compared to patent ductus arteriosus occlusions or pacemaker implantations (all P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ductus Arteriosus, PatentCardiac CatheterizationDog DiseasesAnimalsDogsRetrospective StudiesRadiation DosageFluoroscopy

Stichwörter der Autor:innen

Air kermaDose area productFluoroscopic-guidedMinimally invasiveOccupational health risk

Autor:innen und Institutionen

  • Department of Clinical Sciences, Colorado State University, Fort Collins, CO 80523, USA. Electronic address: kvpierce@ncsu.edu.
  • Department of Clinical Sciences, Colorado State University, Fort Collins, CO 80523, USA.

Zitieren

APA

Pierce, K. V., Scansen, B. A., & Rao, S. (2023). Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2023.03.005

Vancouver

Pierce KV, Scansen BA, Rao S. Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system. Journal of Veterinary Cardiology. 2023. doi:10.1016/j.jvc.2023.03.005

BibTeX
@article{Pierce2023,
  author = {Pierce, K V and Scansen, B A and Rao, S},
  title = {Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system},
  journal = {Journal of Veterinary Cardiology},
  year = {2023},
  doi = {10.1016/j.jvc.2023.03.005}
}
Kostenlos starten →