Transcatheter Amplatz canine duct occluder placement for patent ductus arteriosus occlusion: a retrospective analysis of outcomes and complications in 200 dogs
Journal of Veterinary Cardiology · 2025
DOI: 10.1016/j.jvc.2025.05.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2025. Verfasst von M Ciccozzi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University of Minnesota, Veterinary Medical Center, 1365 Gortner Ave, St Paul, MN 55108, USA. Electronic address: cicco019@…. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent, Dog Diseases, Septal Occluder Device, Cardiac Catheterization. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The Amplatz canine duct occluder (ACDO) is routinely used for patent ductus arteriosus (PDA) occlusion. Limited data are available on clinical outcomes and success rates with ACDO device placement. This study aimed to determine procedural outcome and complications for PDA occlusion with the ACDO in a large cohort of dogs. ANIMALS, MATERIALS, AND METHODS: A retrospective study of 200 dogs that underwent ACDO placement for PDA occlusion between March 2007 and September 2023 was conducted. Transthoracic echocardiography was performed prior to occlusion, 24 h after occlusion, and during follow-up recheck visits. Procedural success was defined as successful device placement as determined based on fluoroscopy at the time of the PDA occlusion procedure and survival after the procedure. RESULTS: Dogs had a median weight of 6.5 kg and required a median device size of 6 mm. At 24 h post occlusion, 5% of dogs had trivial flow through the device. Persistent trivial flow was noted on recheck in 5.5% of patients with a median follow-up time of 96 days. Minor complications occurred in 2.5% of dogs. Major complications occurred in 4% of dogs including device embolization in 2% of dogs. Procedural mortality rate was 0.5%. There was a statistically significant reduction in left ventricular and left atrial size at the 24-h postocclusion recheck echocardiogram (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University of Minnesota, Veterinary Medical Center, 1365 Gortner Ave, St Paul, MN 55108, USA. Electronic address: cicco019@umn.edu.
- Department of Cardiology, University of Minnesota, Veterinary Medical Center, 1365 Gortner Ave, St Paul, MN 55108, USA.
Zitieren
APA
Ciccozzi, M., Stauthammer, C. D., Coats, C., Oberholtzer, S., Masters, A., Gavic, E., Rendahl, A., & Tobias, A. (2025). Transcatheter Amplatz canine duct occluder placement for patent ductus arteriosus occlusion: a retrospective analysis of outcomes and complications in 200 dogs. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2025.05.002
Vancouver
Ciccozzi M, Stauthammer CD, Coats C, Oberholtzer S, Masters A, Gavic E, et al. Transcatheter Amplatz canine duct occluder placement for patent ductus arteriosus occlusion: a retrospective analysis of outcomes and complications in 200 dogs. Journal of Veterinary Cardiology. 2025. doi:10.1016/j.jvc.2025.05.002
BibTeX
@article{Ciccozzi2025,
author = {Ciccozzi, M and Stauthammer, C D and Coats, C and Oberholtzer, S and Masters, A and Gavic, E and Rendahl, A and Tobias, A},
title = {Transcatheter Amplatz canine duct occluder placement for patent ductus arteriosus occlusion: a retrospective analysis of outcomes and complications in 200 dogs},
journal = {Journal of Veterinary Cardiology},
year = {2025},
doi = {10.1016/j.jvc.2025.05.002}
}
EUVIMED