EUVIMEDEUVIMED entdecken
Vergleichsstudie

External aortic annuloplasty with a dedicated expansible ring improves outcomes in remodeling root repair compared with homemade Dacron ring

Nathanael Shraer, Pouya Youssefi, Luigi Garufi, Mathieu Debauchez, Emmanuel Lansac

The Journal of Thoracic and Cardiovascular Surgery · 2025

DOI: 10.1016/j.jtcvs.2024.06.013 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025. Verfasst von Nathanael Shraer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiac Surgery, Necker APHP Hospital, Paris, France. Electronic address: nshraer@gmail.com. Hauptthemen laut MEDLINE: Polyethylene Terephthalates, Heart Valve Prosthesis, Aortic Valve Insufficiency, Cardiac Valve Annuloplasty. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: In remodeling valve-sparing root replacement with external annuloplasty, we compare long-term outcomes of a calibrated expansible extra-aortic ring with a homemade Dacron ring. METHODS: All patients (2003-2020) operated for root aneurysm with/without aortic insufficiency (AI) were included. The standardized CAVIAAR (conservation aortique valvulaire dans les insuffisances aortiques et anévrysmes de la racine-Valve sparing in aortic insufficiencies and root aneurysms) technique was root remodeling and external annuloplasty ring with the EXTRA-AORTIC Ring or homemade Dacron ring. RESULTS: Among 486 patients (age 52.3 ± 14.0 years) operated for root aneurysm, 375 (repair rate: 77.1%) underwent root remodeling with annuloplasty (extra-aortic ring, n = 289, vs Dacron ring, n = 86). At 10 years (median follow-up, 4.08 years' interquartile range, 1.95-7.61), unmatched and matched analysis showed that patients with extra-aortic ring had greater survival, similar to the general population (93.3% vs 79.9%, P = .097), lower reoperation incidence (2.0% vs 9.7%, P = .0098), and lower AI grade >2 recurrence (1.9% vs 11.2%, P = .0042), compared with patients with a Dacron ring. Mixed-effect model showed that with extra-aortic ring annuloplasty, annular dilation over time (P = .0033) was prevented and, compared with the homemade Dacron ring, root expansibility was better preserved (3.22% vs 2.12%, P = .002) and mean transvalvular gradient was lower (6.58 mm Hg vs 7.94 mm Hg, P = .001). Tricuspid and bicuspid valves with extra-aortic ring had similar reoperation (4.3% vs 0.85%, P = .65) and AI grade >2 incidence (2.7% vs 1.2%, P = .61), expansibility (P = .29), and diameter (P = .47), whereas mean transvalvular gradient was lower for tricuspid valves (5.58 mm Hg vs 7.60 mm Hg, P = .004). CONCLUSIONS: Valve-sparing root remodeling with calibrated expansible extra-aortic ring annuloplasty improves the outcomes of reoperation and recurrent AI compared with a homemade Dacron ring. It prevents dilation and maintains physiological root dynamics for durable valve repair.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyethylene TerephthalatesHeart Valve ProsthesisAortic Valve InsufficiencyCardiac Valve AnnuloplastyAortic ValveBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationAortic AneurysmHumansMaleMiddle AgedFemaleProsthesis DesignTreatment OutcomeAdultAgedRetrospective StudiesTime Factors

Stichwörter der Autor:innen

aortic annuloplastyaortic rootaortic valve repairroot dynamics

Substanzen

Polyethylene Terephthalates

Autor:innen und Institutionen

  • Department of Pediatric Cardiac Surgery, Necker APHP Hospital, Paris, France. Electronic address: nshraer@gmail.com.
  • Department of Cardiac Surgery, St George's University Hospital, London, United Kingdom.
  • Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
  • Department of Cardiovascular and Thoracic Surgery, Pitié-Salpêtrière APHP Hospital, Paris, France.

Zitieren

APA

Shraer, N., Youssefi, P., Garufi, L., Debauchez, M., & Lansac, E. (2025). External aortic annuloplasty with a dedicated expansible ring improves outcomes in remodeling root repair compared with homemade Dacron ring. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2024.06.013

Vancouver

Shraer N, Youssefi P, Garufi L, Debauchez M, Lansac E. External aortic annuloplasty with a dedicated expansible ring improves outcomes in remodeling root repair compared with homemade Dacron ring. The Journal of Thoracic and Cardiovascular Surgery. 2025. doi:10.1016/j.jtcvs.2024.06.013

BibTeX
@article{Shraer2025,
  author = {Shraer, Nathanael and Youssefi, Pouya and Garufi, Luigi and Debauchez, Mathieu and Lansac, Emmanuel},
  title = {External aortic annuloplasty with a dedicated expansible ring improves outcomes in remodeling root repair compared with homemade Dacron ring},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2025},
  doi = {10.1016/j.jtcvs.2024.06.013}
}
Kostenlos starten →