Postoperative scapular neck length is associated with strength and rotational range of motion following reverse total shoulder arthroplasty with the Arthrex Univers Revers
Journal of Shoulder and Elbow Surgery · 2025
DOI: 10.1016/j.jse.2025.10.021 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Annalise D Denard und 5 weiteren Autor:innen. Beteiligte Einrichtung: Southern Oregon Orthopedics, Medford, OR, USA. Hauptthemen laut MEDLINE: Range of Motion, Articular, Arthroplasty, Replacement, Shoulder, Scapula, Shoulder Joint. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Arthrex Inc.
Abstract (Originalsprache)
BACKGROUND: The purpose of this investigation was to evaluate the impact of scapular neck length (SNL) on outcomes following reverse total shoulder arthroplasty (rTSA) using a lateralized 135° implant (Univers Revers; Arthrex Inc.; Naples, FL). Our hypothesis was that increased postoperative SNL would be associated with improved range of motion (ROM) following rTSA. METHODS: A multicenter retrospective study was performed on a prospectively collected database. Inclusion criteria were patients undergoing primary rTSA with minimum 2-year follow-up. Preoperative radiographs were analyzed for SNL and glenoid height. Postoperative radiographs were analyzed for scapular notching, inferior glenosphere overhang, effective SNL defined as the distance from medial glenosphere to lateral column of scapula (MGLS), lateralization shoulder angle, and distalization angle. Patient reported outcomes, ROM, and strength at 2 years postoperatively were correlated with outcomes controlling for demographic variables. MGLS was stratified by 0-5 mm, 5-10 mm, and >10 mm for analysis. RESULTS: A total of 485 patients met inclusion criteria for this investigation. Preoperative SNL was negatively associated with external rotational strength at 2 years postoperatively (P = .039), but was not found to influence patient reported outcomes, ROM, or the incidence of scapular notching (P > .05). Increased postoperative MGLS was positively associated with active internal rotation to the highest spinal level (P = .024) and belly press strength (P 10 mm (P = .011) and improved belly press strength was observed with a postoperative MGLS of >5 mm (P 10 mm group compared to the 0-5 mm (L3 vs. L4; P 10 mm compared to the 5-10 mm group (73° vs. 57°; P = .013). CONCLUSION: Increased effective postoperative SNL, or MGLS, is positively associated with rotational ROM and shoulder strength and following rTSA with the Arthrex Univers Revers. Postoperative MGLS of >10 mm is associated with increased Constant strength and belly press strength compared to an MGLS of 0 to 5 mm. The differences in external rotation at 90° in the >10 mm group compared to the 5-10 mm group and for the internal rotation in the 10 mm group compared to the 0-5 mm group met criteria for a substantial clinical benefit.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Southern Oregon Orthopedics, Medford, OR, USA.
- Department of Orthopaedic Surgery, University of Virginia School of Medicine, VA, USA; Shoulder Arthroplasty Research Committee Group.
- Twin Cities Orthopedics, Chaska, MN, USA.
- Department of Orthopaedic Surgery, University of Virginia School of Medicine, VA, USA.
- Shoulder Arthroplasty Research Committee Group; Western Orthopedics, Denver, CO, USA. Electronic address: bwsears@gmail.com.
Förderung
- Arthrex Inc
Zitieren
APA
Denard, A. D., Werner, B. C., Schuette, H. B., DeBruin, A. E., Shoulder 90 Arthroplasty Research Committee (ShARC) group, & Sears, B. W. (2025). Postoperative scapular neck length is associated with strength and rotational range of motion following reverse total shoulder arthroplasty with the Arthrex Univers Revers. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.10.021
Vancouver
Denard AD, Werner BC, Schuette HB, DeBruin AE, Shoulder 90 Arthroplasty Research Committee (ShARC) group, Sears BW. Postoperative scapular neck length is associated with strength and rotational range of motion following reverse total shoulder arthroplasty with the Arthrex Univers Revers. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2025.10.021
BibTeX
@article{Denard2025,
author = {Denard, Annalise D and Werner, Brian C and Schuette, Hayden B and DeBruin, Abbey E and Shoulder 90 Arthroplasty Research Committee (ShARC) group, Shoulder 90 Arthroplasty Research Committee (ShARC) group and Sears, Benjamin W},
title = {Postoperative scapular neck length is associated with strength and rotational range of motion following reverse total shoulder arthroplasty with the Arthrex Univers Revers},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2025},
doi = {10.1016/j.jse.2025.10.021}
}
EUVIMED