Scapular upward rotation during intraoperative functional zero-position assessment in relation to postoperative outcomes and elevated alignment after reverse total shoulder arthroplasty
International Orthopaedics · 2026-12 · 50 (12) · 3227-3235
DOI: 10.1007/s00264-026-07048-y ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, online erschienen am 26.09.2026. Verfasst von Ryo Tazawa und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan. ryotaz@…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Scapula, Shoulder Joint, Rotator Cuff Tear Arthropathy. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Scapulothoracic (ST) compensation is common after reverse total shoulder arthroplasty (rTSA); however, the clinical relevance of intraoperative scapular motion remains unclear. The functional zero-position denotes humeral shaft-scapular spine alignment during passive scaption. This study evaluated whether scapular upward rotation required to achieve this position was associated with postoperative function and elevated alignment. METHODS: We retrospectively analysed 28 shoulders with cuff tear arthropathy treated with rTSA in which the functional zero-position was fluoroscopically confirmed. Scapular upward rotation angle (SURA) during passive scaption was defined as the change in scapular spine orientation from rest to the functional zero-position. Patients were divided into low- and high-SURA groups using the median SURA. Postoperative range of motion, Constant-Murley Score, and zero deviation angle on maximum active elevation radiographs were compared. RESULTS: The median SURA was 30°. Patients were categorised into low-SURA (≤ 30°, n = 15) and high-SURA (> 30°, n = 13) groups. Flexion was greater in the low-SURA group from three months to the final follow-up (all P < 0.05) and abduction from six months to the final follow-up (all P = 0.019). External and internal rotation did not differ. The Constant-Murley Score was higher in the low-SURA group at 1 year (P = 0.015) and at the final follow-up (P = 0.037). The zero deviation angle was smaller in the low-SURA group at the final follow-up (P = 0.037). CONCLUSION: In this exploratory analysis, the low-SURA group demonstrated superior postoperative elevation, higher Constant-Murley Scores, and elevated alignment closer to the functional zero-position. Intraoperative SURA may represent a potential measure of motion balance during rTSA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan. ryotaz@med.kitasato-u.ac.jp.
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan.
ORCID-Profile: Ryo Tazawa, Gen Inoue
Zitieren
APA
Tazawa, R., Kenmoku, T., Matsumoto, M., Inoue, K., Ishii, D., Yoshizawa, T., Konno, Y., Kaneda, T., Inoue, G., & Takaso, M. (2026). Scapular upward rotation during intraoperative functional zero-position assessment in relation to postoperative outcomes and elevated alignment after reverse total shoulder arthroplasty. International Orthopaedics, 50(12), 3227-3235. https://doi.org/10.1007/s00264-026-07048-y
Vancouver
Tazawa R, Kenmoku T, Matsumoto M, Inoue K, Ishii D, Yoshizawa T, et al. Scapular upward rotation during intraoperative functional zero-position assessment in relation to postoperative outcomes and elevated alignment after reverse total shoulder arthroplasty. International Orthopaedics. 2026;50(12):3227-3235. doi:10.1007/s00264-026-07048-y
BibTeX
@article{Tazawa2026,
author = {Tazawa, Ryo and Kenmoku, Tomonori and Matsumoto, Mitsuyoshi and Inoue, Kosuke and Ishii, Daisuke and Yoshizawa, Tai and Konno, Yuta and Kaneda, Tomonori and Inoue, Gen and Takaso, Masashi},
title = {Scapular upward rotation during intraoperative functional zero-position assessment in relation to postoperative outcomes and elevated alignment after reverse total shoulder arthroplasty},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {12},
pages = {3227--3235},
doi = {10.1007/s00264-026-07048-y}
}
EUVIMED