EUVIMEDEUVIMED entdecken
Crossref

Influence of backside seating parameters and augmented baseplate components in virtual planning for reverse shoulder arthroplasty

Brian C Werner, Albert Lin, Timothy R Lenters, David Lutton, R Alexander Creighton, Joshua Port, Scott Doody, Nick Metcalfe, David Knopf

Journal of Shoulder and Elbow Surgery · 2024

DOI: 10.1016/j.jse.2023.10.024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2024. Verfasst von Brian C Werner und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Virginia, Charlottesville, VA, USA. Electronic address: bcw4x@uvahealth.org. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Joint. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Arthrex Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The primary goal of this investigation was to examine the influence of a backside seating percentage variable on volume of reamed bone and contact area in virtual planning for glenoid baseplate placement for reverse total shoulder arthroplasty (RTSA). The secondary goal was to assess how the option of augmented glenoid baseplate components affected reamed volume and cortical contact area of virtually positioned baseplates. METHODS: Nine surgeons virtually planned 30 RTSA cases using a commercially available software system. The 30 cases were chosen to span a spectrum of glenoid deformity. The study consisted of 3 phases. In phase 1, cases were planned with the backside seating percentage blinded and without the option of augmented baseplate components. In phase 2, the backside seating parameter was unblinded. In phase 3, augmented baseplate components were added as an option. Implant version and inclination were recorded. By use of computer-assisted design models, total volume of bone reamed, as well as reamed cortical volume and cancellous volume, was calculated. Total, cortical, and cancellous baseplate contact areas were also calculated. Finally, total glenoid lateralization was calculated for each phase and compared. RESULTS: Mean implant version was clinically similar across phases but was statistically significantly lower in phase 3 (P = .006 compared with phase 1 and P = .001 compared with phase 2). Mean implant inclination was clinically similar across phases but was statistically significantly lower in phase 3 (P < .001). Phase 3 had statistically significantly lower cancellous and total reamed bone volumes compared with phase 1 and phase 2 (P < .001 for all comparisons). Phase 3 had statistically significantly larger cortical contact area, lower cancellous contact area, and larger total contact area compared with phase 1 and phase 2 (P < .001 for all comparisons). Phase 3 had significantly greater glenoid lateralization (mean, 10.5 mm) compared with phase 1 (mean, 7.8 mm; P < .001) and phase 2 (mean, 7.9 mm; P < .001). CONCLUSIONS: Across a wide range of glenoid pathology during virtual surgical planning, experienced shoulder arthroplasty surgeons chose augmented baseplates frequently, and the option of a full-wedge augmented baseplate resulted in statistically significantly greater correction of glenoid deformity, improved total and cortical baseplate contact area, less cancellous reamed bone, and greater glenoid lateralization. Backside seating information does not have a significant impact on how glenoid baseplates are virtually positioned for RTSA, nor does it impact the baseplate contact area or volume of reamed bone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderShoulder JointHumansProsthesis DesignFemaleMaleSurgery, Computer-AssistedShoulder ProsthesisAgedMiddle AgedComputer-Aided Design

Stichwörter der Autor:innen

Reverse shoulder arthroplastyaugmented baseplatebackside seatingcomputed tomography planningglenoid baseplatereaming

Autor:innen und Institutionen

  • University of Virginia, Charlottesville, VA, USA. Electronic address: bcw4x@uvahealth.org.
  • University of Pittsburgh, Pittsburgh, PA, USA.
  • Trinity Health, Grand Rapids, MI, USA.
  • Washington Circle Orthopaedic Associates, Washington, DC, USA.
  • University of North Carolina-Chapel Hill, Chapel Hill, NC, USA.
  • University Orthopaedics Center, Altoona, PA, USA.

Förderung

  • Arthrex Inc

Zitieren

APA

Werner, B. C., Lin, A., Lenters, T. R., Lutton, D., Creighton, R. A., Port, J., Doody, S., Metcalfe, N., & Knopf, D. (2024). Influence of backside seating parameters and augmented baseplate components in virtual planning for reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2023.10.024

Vancouver

Werner BC, Lin A, Lenters TR, Lutton D, Creighton RA, Port J, et al. Influence of backside seating parameters and augmented baseplate components in virtual planning for reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2024. doi:10.1016/j.jse.2023.10.024

BibTeX
@article{Werner2024,
  author = {Werner, Brian C and Lin, Albert and Lenters, Timothy R and Lutton, David and Creighton, R Alexander and Port, Joshua and Doody, Scott and Metcalfe, Nick and Knopf, David},
  title = {Influence of backside seating parameters and augmented baseplate components in virtual planning for reverse shoulder arthroplasty},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2024},
  doi = {10.1016/j.jse.2023.10.024}
}
Kostenlos starten →