EUVIMEDEUVIMED entdecken
Crossref

Femoral head allograft for glenoid bone loss in primary reverse shoulder arthroplasty: functional and radiologic outcomes

Roberto Castricini, Michele Mercurio, Olimpio Galasso, Valentina Sanzo, Marco De Gori, Massimo De Benedetto, Nicola Orlando, Giorgio Gasparini

Journal of Shoulder and Elbow Surgery · 2024

DOI: 10.1016/j.jse.2023.06.027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2024. Verfasst von Roberto Castricini und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedic and Trauma Surgery, "Villa Verde", Fermo, Italy. Hauptthemen laut MEDLINE: Shoulder Joint, Arthroplasty, Replacement, Shoulder, Glenoid Cavity. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS: We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS: After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION: The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shoulder JointArthroplasty, Replacement, ShoulderGlenoid CavityHumansFemur HeadRetrospective StudiesScapulaPostoperative ComplicationsAllograftsTreatment OutcomeRange of Motion, Articular

Stichwörter der Autor:innen

3-dimensional (3D) modelReverse shoulder arthroplastybaseplate failurebone graftfemoral head allograftglenoid bone losspatient-specific instrumentation

Autor:innen und Institutionen

  • Division of Orthopaedic and Trauma Surgery, "Villa Verde", Fermo, Italy.
  • Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy.
  • Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy. Electronic address: galasso@unicz.it.
  • Department of Orthopaedic and Trauma Surgery, Basso Ionio Hospital, Soverato, Italy.

Zitieren

APA

Castricini, R., Mercurio, M., Galasso, O., Sanzo, V., De Gori, M., De Benedetto, M., Orlando, N., & Gasparini, G. (2024). Femoral head allograft for glenoid bone loss in primary reverse shoulder arthroplasty: functional and radiologic outcomes. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2023.06.027

Vancouver

Castricini R, Mercurio M, Galasso O, Sanzo V, De Gori M, De Benedetto M, et al. Femoral head allograft for glenoid bone loss in primary reverse shoulder arthroplasty: functional and radiologic outcomes. Journal of Shoulder and Elbow Surgery. 2024. doi:10.1016/j.jse.2023.06.027

BibTeX
@article{Castricini2024,
  author = {Castricini, Roberto and Mercurio, Michele and Galasso, Olimpio and Sanzo, Valentina and De Gori, Marco and De Benedetto, Massimo and Orlando, Nicola and Gasparini, Giorgio},
  title = {Femoral head allograft for glenoid bone loss in primary reverse shoulder arthroplasty: functional and radiologic outcomes},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2024},
  doi = {10.1016/j.jse.2023.06.027}
}
Kostenlos starten →