Reliability of static and dynamic balance assessments using the FootWork Pro pressure® platform in a clinical setting
Journal of Science and Medicine in Sport · 2025
DOI: 10.1016/j.jsams.2025.08.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Science and Medicine in Sport, 2025. Verfasst von Danique J J van Gulick und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Science and Data-analysis, Rondom Podotherapeuten, Podiatric Primary Care Center, the Netherlands; Department of Epidemiology and Data …. Hauptthemen laut MEDLINE: Postural Balance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVES: The objective of this study was to evaluate the reliability and feasibility of static and dynamic balance assessments using the FootWork Pro® pressure platform in healthy adults, along with the impact of protocol variations on reliability. DESIGN: Cross-sectional study among healthy adults (n = 61), in a clinical setting. METHODS: We collected six static balance parameters under four different conditions (eyes open and closed both at 30 and 60 s), and 15 dynamic balance parameters each during two test sessions, with one week in between. Intra-session (i.e., within session) and inter-session (i.e., between sessions) reliability was assessed using intraclass correlation coefficients, and standard errors of measurement, which were calculated up to three trials (static) and five steps (dynamic) to determine the required measurements. An intraclass correlation coefficient of ≥0.70 was considered acceptable. RESULTS: Three trials were required to obtain reliable (averaged) scores for 23 out of 24 static balance parameters (96 %) intra-session, and 15 out of 24 (63 %) inter-session. However, some static parameters show high standard errors of measurement, up to 57.6 % of the (low) mean/median. We found comparable intraclass correlation coefficients for different sample durations. Nine out of 15 dynamic balance parameters (60 %) intra-session could be reliably retrieved by averaging four steps, and ten out of 15 (67 %) inter-session by averaging five steps. CONCLUSIONS: A wide range of static and dynamic balance parameters can be reliably obtained in a clinical setting using the FootWork Pro® pressure platform, averaging three trials and five steps. Reliability does not increase with static sample durations longer than 30 s.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Science and Data-analysis, Rondom Podotherapeuten, Podiatric Primary Care Center, the Netherlands; Department of Epidemiology and Data Science, University Medical Center Amsterdam, Amsterdam Public Health…
- Department of Rehabilitation Medicine, University Medical Center Amsterdam, Amsterdam Movement Sciences Research Institute, Vrije Universiteit, the Netherlands.
- Department of Epidemiology and Data Science, University Medical Center Amsterdam, Amsterdam Public Health Research Institute, University of Amsterdam, the Netherlands.
Zitieren
APA
van Gulick, D. J. J., van der Leeden, M., Lucas, C., & Stuiver, M. M. (2025). Reliability of static and dynamic balance assessments using the FootWork Pro pressure® platform in a clinical setting. Journal of Science and Medicine in Sport. https://doi.org/10.1016/j.jsams.2025.08.006
Vancouver
van Gulick DJJ, van der Leeden M, Lucas C, Stuiver MM. Reliability of static and dynamic balance assessments using the FootWork Pro pressure® platform in a clinical setting. Journal of Science and Medicine in Sport. 2025. doi:10.1016/j.jsams.2025.08.006
BibTeX
@article{vanGulick2025,
author = {van Gulick, Danique J J and van der Leeden, Marike and Lucas, Cees and Stuiver, Martijn M},
title = {Reliability of static and dynamic balance assessments using the FootWork Pro pressure® platform in a clinical setting},
journal = {Journal of Science and Medicine in Sport},
year = {2025},
doi = {10.1016/j.jsams.2025.08.006}
}
EUVIMED